> 09.28 Pirani 1.00e-3 mbar IE514 5.45e-8 mbar > > 12.10 Bakeout tent frame installed > SAES UHV1400 NEG pump power cables #1-6 installed > See attachments 1 & 2 > > 16.35 Attachments 3-6 > upstream baseplate > 3x sets of heaters beneath CARME chamber connected to CRYRING heater/TC manifold - attachments 7-8 > > > 16.45 Pirani 1.00e-3 mbar IE514 4.80e-8 mbar > > > 17.10 SAES D-2000 #1 downstream, outside NEG power + HV ( attachment 9 - OK cable connector ) > SAES D-2000 #3 downstream, inside NEG power + HV > SAES D-2000 #4 upstream, inside HV > SAES D-2000 #2 upstream, outside HV > > 2x ( of 4x ) SAES D-2000 neg power cables were broken - forward-shell detached (unscrewed ) from back-shell remaining attached to D-2000 neg power connector. > Re-assembly is straightforward but it is unclear how the 6x female sockets are aligned with the connector keys of the forward-shell (attachments 10-11 cf. attachment 9). > Until this is understood these 2x SAES D-2000 neg power cables should not be used.