AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
CARME |
 |
|
Message ID: 476
Entry time: Fri Jan 19 11:17:50 2024
|
Author: |
JG, TD |
Subject: |
Friday 19 January |
|
|
12.20 CARME IE514 4.1e-11mbar, ambient temperature 16.7 deg C
FEE64 cabling complete
WR source - VETAR2 borrowed from Nik Kurz and opwerating standalone ( no BuTIS reference )
All MACBs mode 0x3
15.20 Power ON FEE64s #1 - #15
aida02 did not boot - /etc/dhcp/dhcpd.conf typo - fixed
aida04 did not boot - AIDA FEE64 PSU output #4 fuses open circuit - fuses replaced from AIDA FEE64 PSU spare channel ( aida16 not connected yet ) - fixed
aida07 did not boot - power OK - FEE64 comfort LEDs OK - network switch link LED OK - network config?
aida08 boots - power OK - comfort LEDs OK - network switch link LED OK - requests RFS / but does not request RFS MIDAS - can ping aida08 OK, cannot telnet aida08 'connection refused'
aida09 did not boot - FEE64 comfort LEDS OFF - swap FEE64 #9 & #10 power cables - aida09 boots OK, aida10 does not boot
Restore #9 & #10 power cables - swap AIDA FEE64 outputs #1 & #2 ( aida09 & aida10 ) - aida09 boots OK
Conclude AIDA FEE64 PSU ( no label ) output #1 is faulty. Replace AIDA FEE64 PSU ( label ISOL3 ). aida09 & aida10 boot OK
aida15/aida16 MAC addresses were swapped in https://elog.ph.ed.ac.uk/CARME/467 - fixed
aida01-aida06, aida09-aida15 boot OK - aida07 does not boot, aida08 does not complete boot
16.25 Configure MIDAS DEE64 servers aida01 - aida06, aida10 - aida15
FEE64 temperatures - attachment 1
aida06 looks low ( c. 25 deg C cf. c. 40 deg C )
System wide checks - attachments 2-8
aida02 fails WR decoder
WR timestamps ( attachments 7 & 8 ) look odd/low - values always c. 0x2???
17.30 CARME IE514 OFF
WR NIM emulator SMA cables to root MACB ( rear panel ) disconnected at front panel
Power cycle FEE64s
System wide checks & WR timestamp control - attachments 9-14
no change
17.45 Detector bias -20, -100 & 150V - attachments 15-17
CAEN N1419ET non-floating outputs ( to be checked ), HV cable SHV - 2x Lemo 00.250, LK1 not fitted
18.40 Detector bias -150V attachment 18
To Do
Check ASIC settings
Configure HV
Check LKs
Ground cabling
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|