Entry time:
Fri Feb 2 08:59:36 2024
Author
*
:
Subject
*
:
Current pulser widths excel spreadsheet attached 09.58 DSSSD bias OK - attachment 1 Ambient temperature +16.1 deg C FEE64 temps OK - attachment 2 ADC data item stats OK - attachment 3 aida15 asic #2 high rate - asic u/s system wide tests OK *except* aida09 - attachments 4-5 aida09 WR status 0x20 aida09 WR timestamp incorrect cf. all other FEE64s per FEE64 Rate spectra - attachment 6 per FEE64 1.8.L spectra - attachments 7-8 aida14 pulse peak witdh 58 ch FWHM aida11 pulse peak witdh 48 ch FWHM per FEE64 1.8.W spetra - 20us FSR - attachments 9-10 12.00 aida09 WR timestamp issue resolved by FEE64 reboot 14.10 Safety pins removed from detector motion system. CB performs one, complete DSSSD movement cycle. Zero all histogram and stats per FEE64 Stat spectra ( log scale ) and ADC data item stats for the complete DSSSD movement cycle - attachments 11-12 No change observed in DSSSD leakage currents during DSSSD movement cycle. 15.35 Resolved issue from previous elog. Begin background run writing data to disk. ASIC check load Start DAQ G22-88/R1 background alpha EG&G Ortec 448 Pulser OFF ASIC settings 2024Jan20-12.02.08 slow comparator 0x64 ( all FEE64s *except aida15 asic #2 0xff ) All histograms set to zero DSSSD bias OK - attachment 13 FEE64 temps OK - attachment 14 WR timestamps OK - attachment 15 ADC data item stats - attachment 16 aida15 asic #2 u/s - rate c. 250k ADC data items/s Merger, Tape Server & Merger stats - attachments 17-19 data rate to disk c. 2Mb/s dominated by aida15 asic 2
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
Screenshot_from_2024-02-02_09-59-10.png
Original size: 734x499
Attachment 2:
Screenshot_from_2024-02-02_10-10-46.png
Original size: 1920x1014
Attachment 3:
Screenshot_from_2024-02-02_10-10-59.png
Original size: 1920x1014
Attachment 4:
Screenshot_from_2024-02-02_10-11-18.png
Original size: 1920x1014
Attachment 5:
Screenshot_from_2024-02-02_10-11-37.png
Original size: 1920x1014
Attachment 6:
Screenshot_from_2024-02-02_10-12-32.png
Original size: 1920x1014
Attachment 7:
Screenshot_from_2024-02-02_10-13-17.png
Original size: 1920x1014
Attachment 8:
Screenshot_from_2024-02-02_10-15-11.png
Original size: 1920x1014
Attachment 9:
Screenshot_from_2024-02-02_10-16-33.png
Original size: 1920x1014
Attachment 10:
Screenshot_from_2024-02-02_10-18-01.png
Original size: 1920x1014
Attachment 11:
Screenshot_from_2024-02-02_14-09-42.png
Original size: 1920x1014
Attachment 12:
Screenshot_from_2024-02-02_14-09-46.png
Original size: 1920x1014
Attachment 13:
Screenshot_from_2024-02-02_15-41-14.png
Original size: 734x499
Attachment 14:
Screenshot_from_2024-02-02_15-41-35.png
Original size: 1920x1014
Attachment 15:
Screenshot_from_2024-02-02_15-42-14.png
Original size: 1920x1014
Attachment 16:
Screenshot_from_2024-02-02_15-42-31.png
Original size: 1920x1014
Attachment 17:
Screenshot_from_2024-02-02_15-43-02.png
Original size: 3840x1080
Attachment 18:
Screenshot_from_2024-02-02_15-43-11.png
Original size: 1920x1014
Attachment 19:
Screenshot_from_2024-02-02_15-43-25.png
Original size: 1920x1014
Attachment 20:
Pulser-widths-carme-2024.xlsx
Attachment 21:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown