AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME  ELOG logo
Message ID: 493     Entry time: Mon Feb 5 19:43:52 2024
Author: CB, TD, ML 
Subject: BuTIS reference for VETAR2 
16.40 CB/ML install fibre optic cable from patch panel beneath dipole downstream of YR09/CARME chamber to VETAR2 front panel fibre connector - see attachments 1 & 2.

VETAR2 LCD display changes from magenta to cyan.

DAQ stop. DAQ reset. DAQ setup.

All system wide checks OK.

WR timestamp control - attachment 3 is timed 16.43.11 UTC+1

WR timestamp 0x17B101E7 7FCD1ACD -> 1707147827543349965ns -> 1707147827s -> Monday, February 5, 2024 3:43:47 PM UTC ( https://www.epochconverter.com/ )
Attachment 1: 20240205_173029.jpg  1.523 MB  | Hide | Hide all
20240205_173029.jpg
Attachment 2: 20240205_172957.jpg  2.218 MB  | Hide | Hide all
20240205_172957.jpg
Attachment 3: Screenshot_from_2024-02-05_16-43-18.png  218 kB  | Hide | Hide all
Screenshot_from_2024-02-05_16-43-18.png
ELOG V3.1.4-unknown