Entry time:
Sat Aug 16 22:30:41 2025
Author
*
:
Subject
*
:
> > 22.51 DAQ continues file G22-86/R35_36 > > DSSSD bias OK - attachments 1-2 > > FEE64 temperatures - attachments 3-4 > CRYRING hall ambient temperature 20 > FEE64 temps tracking ambient temperature - aida01, aida03, aida09 and aida15 - all ( just ) over 65 deg C > > All system wide checks OK > > WR timestamps OK - attachment 5 > > ADC, DISC and PAUSE data item stats - attachments 6-8 > hot channels aida01 ( 91k ), aida04 ( 12k ), aida15 ( 11k ) > > per FEE64 Rate spectra - attachments 9-10 > aida04 & aida13 only FEE64s with significant rates and systematic rate variation with channel # > > per FEE64 1.8.L, 1.8.H and 1.8.W 20us FSR spectra - attachments 11-16 > > Merger, Merger stats and TapeServer OK - attachments 17-19 > > 23.16 All histograms, stats and merger stats zero'd > > Online analysis spectra - attachments 21-26 > only the inner quadrants of the 4x DSSSDs are correctly mapped - attachment 21 > observe double peak structure in DSSSD0 rate spectra - radiation damage most forward lab angle strips? - attachment 24 > > 23.23 restart online analysis - zero spectra > > 23.30 YR12DTIC 2.5e7/s > YR09 vacuum 7e-11 - 1.2e-10 mbar > density 4e11/cm2 > See attachments 27-34 > > > > 01.30 DAQ continues file G22-86/R35_39 > > FEE64 temperatures - attachments 35-36 > > ADC data item stats - attachment 37 > > DSSSD leakage currents - attachment 38 > > YR12DTIC 2.5e7/s > YR09 vacuum 7e-11 - 1.2e-10 mbar > density 4.1e11/cm2 > > > 03.05 YR12DTIC 2.2e7/s > YR09 vacuum 7e-11 - 1.2e-10 mbar > density 3.5e11/cm2 > > DAQ continues file G22-86/R35_42 > > DSSSD leakage currents - attachment 39 > > FEE64 temperatures - attachments 40-41 > > ADC data item stats - attachment 42 > > 05.05 DAQ continues file G22-86/R35_47 > > YR12DTIC 2.5e7/s > density 3.8e11/cm2 > > DAQ continues file G22-86/R35_42 > > DSSSD leakage currents - attachment 43 > > FEE64 temperatures - attachments 44-45 > > ADC data item stats - attachment 46 > > per FEE64 Rate spectra - attachments 47-48 > aida12 asic #1 and # 2 HEC activity > and following Check ASIC load aida12 > > ADC data item stats - attachment 49 > > > Shift Summary > > Beam, target density and vacuum appear to have been stable overnight > > FEE64 temperatures continue to cycle > > Evidence of some radiation damage DSSSDD 0 presumably for most forward lab angle strips? > > aida12 asic #1 and #2 high rate HEC activity - fixed by ASIC check load
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown