AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
CARME
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Apr 5 12:12:16 2025
Author
*
:
Subject
*
:
<p>09:43</p> <p>Run 44 started cooled beam on target</p> <p>Detectors IN (left arm pot =36.5 mm, right arm pot = 70.49 mm). Stationary. Same as previous runs</p> <p>Electron cooler voltage 751.4 V this corresponds to 1.3436 MeV/u. This should be back on the peak of the resonance.</p> <p>Target density is 5.2e11 at/cm2, ring pressure looks OK YR09 1.72e-10 mbar. Target density is not very stable and requires small corrections in the x position to maintain a target</p> <p>Horizontal beam position is -7.5 mm, vertical beam position is 0.0 mm. Same as previous run</p> <p>Beam is in the ring for 6 seconds and total cycle time between injections is 10 seconds. Notice this is different than previous runs. Aim is to have a few different cycle time configurations to see effect on halo</p> <p>Statistics, merger statistics, histograms all zero'd</p> <p>10:05</p> <p>FEE temps OK</p> <p>System checks OK</p> <p>Merger OK, tape server OK</p> <p>Leakage current plot attachment 1</p> <p>ADC data items stats attachment 2</p> <p>Monitoring code rates attachment 3</p> <p>11:08</p> <p>FEE temps OK</p> <p>System checks OK</p> <p>Merger OK, tape server OK</p> <p>Leakage current OK</p> <p>ADC data items stats OK</p> <p>Online spectra OK</p> <p>12:30</p> <p>FEE temps OK</p> <p>System checks OK</p> <p>Merger OK, tape server OK</p> <p>Leakage current OK</p> <p>ADC data items stats OK</p> <p>Online spectra OK</p> <p>14:03</p> <p>FEE temps OK</p> <p>System checks OK</p> <p>Merger OK, tape server OK</p> <p>Leakage current OK</p> <p>ADC data items stats OK</p> <p>Online spectra OK</p> <p>15:36</p> <p>FEE temps OK, system checks OK, merger OK,</p> <p>Screenshot 4: temperatures</p> <p>Screenshot 5: statistics</p> <p>Screenhot 6 - 9: spectra (there is a persistent peak in aida13 in Layout8)</p> <p>Screenshot 10: leakage current (current 1 seems to be going up slowly but steadily)</p> <p>Screenshot 11: spectrum</p> <p> </p> <p>17:18</p> <p>FEE temps OK, system checks OK, merger OK,</p> <p>Screenshot 12: temperatures</p> <p>Screenshot 13: statistics</p> <p>Screenhot 14 - 17: spectra (we still see a peak in aida13 in Layout8, but not always)</p> <p>Screenshot 18: leakage current (current 1 seems to be going up slowly but steadily)</p> <p>Screenshot 19: spectrum</p> <p> </p> <p>19:27</p> <p>FEE temps OK, system checks OK, merger OK,</p> <p>Screenshot 20: temperatures</p> <p>Screenshot 21: statistics</p> <p>Screenhot 22 - 25: spectra (we still see a peak in aida13 in Layout8, but not always)</p> <p>Screenshot 26: leakage current (current 1 seems to be going up slowly but steadily)</p> <p>Screenshot 27: spectrum</p> <p> </p> <p>21:57</p> <p>FEE temps OK, system checks OK, merger OK,</p> <p>Screenshot 28: temperatures</p> <p>Screenshot 29: statistics</p> <p>Screenhot 30 - 33: spectra (we still see a peak in aida13 in Layout8, but not always)</p> <p>Screenshot 34: leakage current</p> <p>Screenshot 35: spectrum</p> <p> </p> <p> </p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown