<p>07:00</p>
<p>Run 12 started. D+ beam is incident on the target at 1.5 MeV</p>
<p>Beam intensity in the ring is ~4e7 particles</p>
<p>Target density shows some fluctuations but is ~1e11 atoms/cm2. Target temp 35K</p>
<p>Detectors are positioned fully out (Left arm 18.86mm and right arm 19.8 mm ) and are not moving</p>
<p>Ring pressure looks OK, YR09 E target sensor seems unaffected by the target currently reads ~5e-11 mbar.</p>
<p>Beam is in the ring for ~15s.</p>
<p>Temps and system checks OK</p>
<p>Leakage current OK</p>
<p>Merger and tape server OK</p>
<p>Horizontal beam position 8 mm and vertical beam position 0mm for overlap with target.</p>
<p>Statistics - attachment 1</p>
<p>Energy histogram - attachment 2</p>
<p>XY plot - attachment 3</p>
<p>We see high rate at 1.5 MeV in left dssds but very little in right dssds. XY plots also show counts are concerntrated in a very circular distribution.</p>
<p>07:15</p>
<p>Gleb has just called and requires access to the cave to check on a turbo pump in the source.</p>
<p>Ring vacuum looks good</p>
<p>Beam will be down for 10-15 minutes only hopefully. </p>
<p>07:45</p>
<p>Beam is back in the ring but injection requires optimisation.</p>
<p>09:00</p>
<p>There are some issues with the source that require a few hours to resolve. Potentially until 7 or 8 pm tonight. We have about an hour before work starts.</p>
<p>We have done a quick test of the motors and moved the left and right arms in using the pnuematic only.</p>
<p>New position left arm = 62.71 mm , right arm = 64.6 mm.</p>
<p>We observed the rates in left detectors went up significantly. In the right detectors we observed little increase.</p>
<p>See attached xy plot - attachment 4</p>
<p>See attached energy histogram - attachment 5</p>
<p>Beam intensity has dropped significantly - below 1e6 particles so even at in positons we see few counts at the moment.</p>
<p>09:25</p>
<p>Source has degraded pretty rapidly so beam will be stopped for now.</p>
<p>Detectors moved back out.</p>
<p>Target nozzle moved from X= -13000, Y=2500 to X= -11000, Y=2500. S1 has dropped to 5e-10 mbar.</p>
<p>Note Gleb mentioned that last night it was likely a large proportion of the ions stored were molecular hydrogen not deuterium.</p>
<p>16:18</p>
<p>Temps and system checks OK</p>
<p>Leakage current OK</p>
<p>Merger and tape server OK</p>
<p> </p>
<p>18:10</p>
<p>Temps and system checks OK</p>
<p>Leakage current OK</p>
<p>Merger and tape server OK</p>
<p> </p>
<p>19:38</p>
<p>Operators are trying to optimize some beam. For now the beam is lower than it should be probably because is easy to work with the source like that.</p>
<p>Temps and system checks OK</p>
<p>Leakage current OK</p>
<p>Merger and tape server OK</p>
<p><br />