AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
CARME
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Fri Aug 8 04:01:39 2025
Author
*
:
Subject
*
:
FONT
Arial
Comic Sans MS
Courier New
Tahoma
Times New Roman
Verdana
SIZE
1
2
3
4
5
6
COLOR
blue
dark-blue
orange
red
dark red
green
dark-green
pink
purple
chocolate
[quote]An MBS DAQ is running to collect two types of data: 1. WR timestamps for machine events (injection, target ON/OFF, ...) These are triggering the MBS individually. 2. Scaler rates for machine parameters (target pressures, ring RF, ...) These are being readout each second by a 1Hz trigger. [H2]DAQ quick manual[/H2] MBS node: cry_exp@r4l-70.gsi.de directory: /esr/usr/cry_exp/2025_JET_CARME/mbs DAQ running on: cry_exp@atppc028.gsi.de in a screen session named "jetDAQ" RFIO server: cry_exp@atppc028.gsi.de in a screen session named "RFIO" directory: /u/cry_exp/Beamtimes/202505_Li/lmd RESTART DAQ on cry_exp@atppc028: 1. cd /u/cry_exp/Beamtimes/202505_Li 2. ./daqstart.sh ENTER jetDAQ or RFIO screen on cry_exp@atppc028: - screen -x jetDAQ - screen -x RFIO [H2]cabling documentation[/H2] [H3]MBS trigger inputs[/H3] [TABLE border="1"] trig. type | event |- 1 (PENDING) | ring injection |- 2 (PENDING) | detectors IN |- 3 (PENDING) | detectors OUT |- 4 (PENDING) | target ON (shutter)* |- 5 (PENDING) | target OFF (shutter)* |- 6 (PENDING) | beam dumped |-| |- 11 (PENDING) | 1Hz scaler readout [/TABLE] *The GENESYS signal logic for the target shutter was changed several times, this means trigger 4 and 5 could be swapped. The motor signals (trigger 2 and 3), however, have not been touched and should be stable. [H3]scaler inputs[/H3] [TABLE border="1"] scaler ch. | rate/signal |- 1 | gas jet E1 (inlet pressure zone 1) |- 2 | gas jet E2 (inlet pressure zone 2) |- 3 | gas jet E3 (inlet pressure zone 3) |- 4 | gas jet E4 (inlet pressure zone 4) |- 5 | gas jet S1 (outlet pressure zone 1) |- 6 | gas jet S2 (outlet pressure zone 2) |- 7 | gas jet S3 (outlet pressure zone 3) |- 8 | gas jet S4 (outlet pressure zone 4) |- 9 | gas jet T1 |- 10 | gas jet T2 |- 11 | gas jet VV1 |- 12 | gas jet ?? |- 13 | Scintillator rate (0 deg. det. YR09) [ONLY AFTER 12-06-2025 16:30] |- 14 | - |- 15 | - |- 16 | - |- 17 | cryring IMP horizontal |- 18 | cryring IMP vertical |- 19 | cryring PCT |- 20 | cryring ICT int |- 21 | cryring BPM int |- 22 | cryring Schottky span 0 |- 23 | cry-radio |- 24 | cryring RF |- 25 | - |- 26 | - |- 27 | - |- 28 | - |- 29 | - |- 30 | - |- 31 | - |- 32 | - [/TABLE][/quote]
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown