| <p>Run 48 started. Everything is running again. We started at 3E13 at/cm2</p>
<p>D+ beam deuterium target. D+ beam energy is still 0.5 MeV/u. (beam calc calculation is 0.5143 MeV/u). See previous entry for beamcalc.</p>
<p>All four detectors positioned fully out and stationary, however we switched off detector #4.</p>
<p>Left potentiometer = -3.03mm (corresponds to x = 0, which is the more trustworthy value)</p>
<p>Right potentiometer = 1.74 mm (corresponds to y = -500, which is the more trustworthy value)</p>
<p>Ring cycle time is 10 seconds.</p>
<p>Cooler set value = 297.2 V, 8 mA. Read value = 296.7 V, 7 mA</p>
<p>All leakage currents look good (except dssd4, currently turned off)</p>
<p>Beam position. Vertical =0.0mm , Horizontal=0.0 mm</p>
<p>Data rate ~ 108kB/s</p>
<p> </p>
<p>16:40 Change Gasjet target Y=-500 to Y=0<br />
17:37 Change Gasjet target Y= 0 to Y= 500<br />
<br />
<strong>20:30 We now take some time to optimize the areal density</strong><br />
20:30 Change Gasjet target Y= 500 to Y= 1000 (resulting in 2E12)<br />
20:32 Change Gasjet target Y= 1000 to Y= 500 (resulting in 4E12)<br />
20:33 Change Gasjet target Y= 500 to Y= 0 (resulting in 7E12)<br />
20:35 Change Gasjet target Y= 0 to Y= -500 (resulting in 1.1E13)<br />
20:37 Change Gasjet target Y= -500 to Y= -1000 (resulting in 1.8E13, still increasing and amazing for almost 1h)<br />
<br />
<strong>21:48: Since approximately 20min its just going down systematically from a stable 2E13 to 6E12...) Lets try another round of optimization...</strong><br />
21:48 Change Gasjet target Y= -1000 to Y= -1500 (starting at 7E12 and resulting in 2E12)<br />
21:49 Change Gasjet target Y= -1500 to Y= -1000 (starting at 2E12 and resulting in 6E12)<br />
21:50 Change Gasjet target Y= -1000 to Y= -500 (starting at 6E12 and resulting in 9E12)<br />
21:51 Change Gasjet target Y= -500 to Y= 0 (starting at 9E12 and resulting in 1.3E13 but dropping back to 7E12 within 3min)</p>
<p>21:54 Change Gasjet target. Leaving Y at 0, but moving X from 0 to -500 (starting at 6E12 and resulting in 3E12)<br />
21:55 Change Gasjet target. Leaving Y at 0, but moving X from -500 to 0 (starting at 3E12 and resulting in 4E12)<br />
21:56 Change Gasjet target. Leaving Y at 0, but moving X from 0 to +500 (starting at 4E12 and resulting in 6E12)</p>
<p>21:59 Change Gasjet target. Leaving X at 500, but moving Y from 0 to +500 (starting at 5E12 and resulting in 7E11...)<br />
22:00 Change Gasjet target. Leaving X at 500, but moving Y from +500 to 0 (starting at 7E11 and resulting in 2E12)<br />
<br />
<strong>Side comment:</strong> It seems no matter what we do, that there is a general decrease within the last 30min...</p>
<p>22:00 Change Gasjet target. Leaving X at 500, but moving Y from +500 to 0 (starting at 7E11 and resulting in 2E12)<br />
<br />
<strong>Okay... No matter what we do... Its still decreasing...</strong><br />
<br />
22:03 Change Gasjet target. Leaving Y at 0, but moving X from 500 to 0 (starting at 1E12 and resulting in 2E12)<br />
22:06 Change Gasjet target. Leaving X at 0, but moving Y = 0 from to -500 (starting at 2E12 and resulting in 5E12<br />
22:09 Change Gasjet target. Leaving X at 0, but moving Y = -500 from to -1000 (starting at 5E12 and just randomly fluctuating within the next 15min... and more decreasing than increasing...)<br />
<br />
22:25 Change Gasjet target. Leaving X at 0, but moving Y = -1000 from to -1500 (starting at 1E12 and resulting in 2E12... )<br />
22:31 Change Gasjet target. Leaving X at 0, but moving Y = -1500 from to -2000 (starting at 1E12 and resulting in 8E11... ) Whaaaat????<br />
22:32 Change Gasjet target. Leaving X at 0, but moving Y = -2000 from to -1000 (starting at 9E11 and resulting in 4E12... ) Okaaaay lets wait and see...</p>
<p>01:00</p>
<p>Run stopped.</p>
<p>Final statistics very high. Over 10,000 counts for 3He and 3H, Over 5000 counts for proton.</p>
<p>Final energy histogram and xy plot on final attachments</p> |