Message ID: 755     Entry time: Tue Jun 17 12:22:50 2025
Author: CB EW JG AG SN 
Subject: Run 94/95/96 

Run 94

Background with beam at 150 keV and no target.

Note energy is 0.15% off vs. beam and target to have a more realistic orbit.

As prior run but thresholds changed to

DSSD1 - 0xc

DSSD2 - 0x8

DSSD3 - 0x8

DSSD4 - MEC

 

Run 95

DSSD 4 worked briefly. Tripped again a few minutes into this run. Ignore

 

Run 96 - as run 94

run stopped at 14:00

Zoran reset to with-target settings for later

The plotted readout for the G35 voltage divider over several injections for this run is attached. This kind of data can be obtained from Konstantin also after the experiment.

The average is something like 88.4808 V.

Attachment 1: G35Voltage.pdf  8 kB  Uploaded Tue Jun 17 15:15:21 2025  | Hide | Hide all