Entry time:
Sat Apr 5 07:21:00 2025
Author
*
:
Subject
*
:
Sudden and unexpected power cut at 10:02 German time, affecting all the target hall. It has been caused by the emergency alarm being triggered. Reasons unclear. Electricians were informed. CARME top gate valve closed. 10:33 power is back Set point 120C Scroll on, turbo on (980 Hz normal operation), valve open Pressure at 1.34E-6 mbar No obvious issues. 13:00 Power appears back for the whole ring. Set point 128C Turbo normal operation - no apparent adverse effects of shutdown Pressure at ~3E-7 mbar Pi can again be accessed by ssh. Vacuum plot is updating again.