DESPEC |
 |
|
Message ID: 125
Entry time: Fri Feb 14 12:50:29 2020
|
Author: |
NH |
Subject: |
AIDA Noise 14.02.2020 |
|
|
Electricians changed the grounding for the DESPEC platform to a large pillar that goes deep into soil
Change in grounding was apparently successful at reducing the noise complaints in Cave C (R3B)
AIDA:
Fig 1 & 2: Waveforms (Odd/Even)
Fig 3 & 4: Waveforms Zoomed
Fig 5: Good Event Rate
Fig 6: Merger Rate: 2 M items/sec
Fig 7: HV supply (no change)
There does seem to be a modest improvement (Merger rate down from 3 million, good event rates seem *better*)
(Reminder: AIDA@GSI sends 3 items per each ADC event, so merger rate is higher)
Not sure if this is still where it should stand? |
|
|
|
|
|
|
|
|
|
|
|
|