Author
*
:
Subject
*
:
> > aida09 crashed over the weekend and automatically rebooted. > > After the reboot the WR timestamp sent to the merger is in the future and hence incorrect > > > > Reset/Setup did not fix issue > > Sync ASICs did not fix issue > > GSI White Rabbit control page shows a correct WR timestamp > > > > Attach 1: ttyUSB12 (aida09 log with kernel panic) > > Attach 2: GSI White Rabbit control page > > Attach 3: "Collect All WR Timestamps" > > Attach 4: RAW Display for aida09 > > > > WR Time Item 0x80500232 0x0de48000; Time (48:63)=0x232; Time (28:47)=0x20310; Time (0:27)=0x0de48000 > > WR Time Item 0x80420310 0x0de48000; Time (28:47)=0x20310; Time (0:27)=0x0de48000 > > > > WR Timestamp = 0x23220310de48000 * 10 = 0x15F541EA 8AED0000 = 2020-02-21 CET 01:01:59.699537920 > > c.f. "GSI page" timestamp starting 0x15F427F5 > > > > Attach 5: Timestamp shown by merger > > Tested aida01 and aida09 today ( 19/2/2020 ) and both make sense relative to their Timestamps. > It is the case that the WR timestamp from the "GSI White Rabbit Timestamp" browser window is direct from the White Rabbit decoder and as such has an LSB of > 1nS and is captured at T0 time ( 10uS intervals ) whereas the timestamp of the SYNC in the raw data display is 10nS LSB and is captured at the time of a > logical "rollover" of the lower 14 bits of this 10nS timestamp. > > > Is it the case that the system has been power cycled since aida09 got its timestamp wrong ? > > > It is possible to reset an individual FEE64 WR decoder by writing 0x80 into register 0 of the individual "GSI White Rabbit Timestamp" page. Then 0x1 to re- > enable the decoder. > This should never be necessary as the decoder should be collecting the latest timestamp continuosly. > > The statement remains true however that if the Linux in a FEE64 has a "Panic" then the FEE64 must be powercycled in order for the subsequent data to be > considered reliable. > The Raspberry Pi Console control browser will count the number of "Panics" in the console logged text files so they can be monitored. > > If this occurs again then the system wide check results would be interesting.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown