Message ID: 142
Entry time: Wed Mar 11 17:21:33 2020
|
Author: |
CA, TD, OH |
Subject: |
Wednesday 11 March 16.00-00.00 |
|
|
18.25 DAQ currently running No Storage mode
ASIC settings 2019Oct31-13.24.23
slow comparator 0xa
BNC PB-5 pulser
amplitude 1.0V , attenuator x1
frequency 2Hz
decay time 1ms
DSSSD biases & leakage currents OK - attachment 1
FEE64 temps OK - attachment 2
good events statistics OK - attachment 3
system wide checks - OK
WR timestamp control - attachments 4 & 5
merger & TapeServer OK - attachments 6-8
rate spectra - attachment 9
1.8.L spectra - attachments 10 & 11
aida03 72 ch FWHM
20:36 DSSSD biases & leakage currents OK - attachment 12
FEE64 temps OK - attachment 13
good events statistics OK - attachment 14
all system wide checks ok
21.50 beam starts back up
DAQ running, TapeServer now writing to file R7_0
data rate ~ 25 Mb/s
data forwarding to MBS ok
merger ok, data item rate ~ 2.7 million items/sec
spill time length is now 3 seconds
1500 count rate per spill, ~ 300 Hz implant rate in AIDA
22.35 FEE64 temps OK - attachment 15
good event statistics ok - attachment 16
detector bias/ leakage currents ok - attachment 17
all system wide checks ok
22.47 attachments 18 & 19 - high energy spectra for all FEE64 (1.8.H)
attachment 20 - hit rate spectra for all FEE64
23.02 beam down
on file R7_55
23.11 beam back online
on file R7_61
23.15 system wide checks all ok
detector bias/ leakage currents ok - attachment 21
good event statistics ok - attachment 22
FEE64 temperatures ok - attachment 23 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|