AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
DESPEC |
 |
|
Message ID: 173
Entry time: Fri Mar 5 23:21:59 2021
|
Author: |
CA, OH |
Subject: |
March 6th 2021 00:00 - 08:00 shift |
|
|
00:23 206Hg setting - No beam in AIDA yet
AIDA not writing to file
Data being forwarded to MBS
Fragments expected tonight (?)
00:45 GSI DAQ restart
FEE64 Temps ok - attachment 1
All system wide checks ok
01:00 Good event statistics - attachment 2
01:48 detector biases/ leakage currents - ok - attachment 3
02:10 beam on, plug removed
beam delivered to AIDA
rates spectra - attachment 4
peaks at ~ 10 counts/channel in DSSD1 c.2000Hz
02:20 beam stop
02:26 beam restart - rate spectra - attachment 5
02:43 high energy channel spectra - attachment 6
saved the high energy spectra to layout 2 in spectrum browser
03:00 beam stop
03:08 temperatures ok - attachment 7
statistics ok - attachment 8
bias/leakage currents ok - attachment 9
NewMerger ok - ~4.5M data items merge rate
Tape service ok - ~46MB/s, NoStorage
Data forwarding to MBS ok
all system wide checks ok
04:24 beam is back
rate spectra - attachment 10
04:51 206Hg implanting in DSSD2
Rate spectra - attachment 11
HEC spectra - attachment 12
05:08 temperatures ok - attachment 13
statistics ok - attachment 14
detector bias/leakage currents ok - attachment 15
All system wide checks ok
NewMerger ok - ~4.5M data items merge rate
Tape service ok - ~46MB/s, NoStorage
Data forwarding to MBS ok
05:45 beam stopped
05:50 beam back
06:45 beam running, but no implants in AIDA
possible issues with beam delivery to S4
NewMerger ok - ~4.5M data items merge rate
Tape service ok - ~46MB/s, NoStorage
Data forwarding to MBS ok
07:10 temperatures ok - attachment 16
statistics ok - attachment 17
detector bias/leakage currents ok - attachment 18
all system wide checks OK
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|