Entry time:
Sat Mar 29 11:28:42 2025
Author
*
:
Subject
*
:
> 08:00 ASIC settings 2019Dec19-16.19.51 > DSSSD#1 slow comparator 0xa > DSSSD#2 slow comparator 0xa > DSSSD#3 slow comparator 0xa > > BNC PB-5 Pulser > Amplitude1.0V > Attenuation x1 > Frequency 2Hz > tau_d 1ms > - polarity > Delay 250ns, tail pulse > > > 08:30 - all system wide checks ok > > - Temperatures ok - attachment 1 > > - good event statistics ok - attachment 2 > > - detector bias/leakage currents ok - attachment 3 > > DAQ continues to run - R1_1148 > > Merger ok - 4.6M data items/s > > TapeServer ok - 43MB/s > > 08:55 Giovanna Benzoni - confirms contribution of light ions - attachment 4 see AOQ plots > > 09:19 zeroed all histograms > > writing to file R1_1204 > > FRS on file 72 > > DESPEC to add AIDA XY hit patterns to online analysis histograms > > 09:35 beam stop > > 09:56 beam back > > writing to file R1_1249 > > rate spectra - attachment 5 > > 09:30 AIDA DAQ crashed - lost connection to aida05 > > power cycle and reset > > 09:40 AIDA ok now, writing to file R2 > > 09:50 LS takes over > > 11.10 (German time) > System wide checks produces some fails: > FEE64 module aida06 global clocks failed, 6 (screenshot6) > This error is seen in RIKEN too, tried a RESYNC from master timestamp tab but error still there > > FEE64 module aida06 failed > FEE64 module aida07 failed > Calibration test result: Passed 10, Failed 2 (screenshot7) > Tried a recalibration for the two FEEs in FADC align & control tab but error still there > > Rest of the checks pass > Statistics (screenshot8) > FEE temps okay (screenshot9) > Leakage currents written to sheets (screenshot10) > Merger ~4.5M data items/s > TapeServer ~ 45MB/s > > 13.00 System wide checks produces same fails as last time: > FEE64 module aida06 global clocks failed, 6 > FEE64 module aida06 failed > FEE64 module aida07 failed > Calibration test result: Passed 10, Failed 2 > Rest of the checks are okay > > Statistics (screenshot11) > Spectra rate (screenshot12) > FEE temps okay (screenshot13) > Leakage currents written to sheets (screenshot14) > Merger ~4.5M data items/s > TapeServer ~ 45MB/s > There is 1.5TB left on current drive > > 14.00 beam stopped to look at bPlast, have use the time to change slow comparator threshold > Slow comparators in FEE9-12 raised to 0xd > > > > > > > > > > >
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown