08:00 DAQ continues ok - writing to file R13_120

      Merger ok - 4.6M data items/s

      TapeServer ok - 43 MB/s

08:03 - all system wide checks ok

      - Temperatures ok - attachment 1

      - good event statistics ok - attachment 2

      - detector bias/leakage currents ok - attachment 3

08:08 ASIC settings 2019Dec19-16.19.51
      DSSSD#1 slow comparator 0xa
      DSSSD#2 slow comparator 0xa
      DSSSD#3 slow comparator 0xd

      BNC PB-5 Pulser 
      Amplitude1.0V
      Attenuation x1
      Frequency 2Hz
      tau_d 1ms
      - polarity
      Delay 250ns, tail pulse

08:32 CA briefly lost network connection - back now

08:42 DESPEC on file 102

09:24 Rate spectra - attachment 4

09:32 HEC spectra - attachment 5/6

      beam off - writing to file R13_243

09:42 merger bad timestamp errors - attachment 7

      all system wide checks ok

10:30 NH - Beam was down, I try the new merger from Vic again (R14)
           I made a mistake and had to powercycle fees as they got stuck! aida10 seemed to reboot itslef
           After fixing my mistakes, all running with new merger and rate 15 MB/s (R14)
           It all looked OK even going to MBS/Go4
           I reverted back to original hot merger, R15 and look at the data.
           Beam is now back and I return AIDA to shifters :)

11.30  System wide checks okay except ADC calibration:
       
       FEE64 module aida07 failed
       FEE64 module aida10 failed
       Calibration test result: Passed 10, Failed 2
       If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun 
       calibration for that module

       Reran calibration for both FEEs  but still fail
       Statistics (attachment8)
       Rate spectra (attachment9)
       FEE temps (attachment10)
       Leakage currents written to sheet (attachment11)
       Tapeserver ~33MB/s
       Merger ~ 3.4M items/s
       AIDA file R15_92

11.55 Beam off for a couple minutes but back now

12.00 New Merge terminal disappeared so stopped daq and restarted, and also restarted MBS back working
      Now writing to R16
      Merger ~ 4.5M items/s
      Tapeserver ~44MB/s

12.41 no beam

13.00 DAQ crashed (aida03 no responding), AIDA recovered from power cycle while beam is down
      Beam is back now, forwarding to MBS
      Merger ~ 45M items/s
      Tapeserver ~44MB/s
      Writing to R17

13.20 System wide checks okay except ADC calibration:
       
       FEE64 module aida07 failed
       FEE64 module aida10 failed
       Calibration test result: Passed 10, Failed 2
       If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun 
       calibration for that module

       Statistics (attachment12)
       Rate spectra (attachment13)
       FEE temps (attachment14)
       Leakage currents written to sheet (attachment15)
       Tapeserver ~45MB/s
       Merger ~ 4.4M items/s

14.27 beam off
      file R17_115
      back a couple minutes later

14.40 no beam again back at 14.46

15.40 System wide checks okay except ADC calibration:
       
       FEE64 module aida07 failed
       FEE64 module aida10 failed
       Calibration test result: Passed 10, Failed 2
       If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun 
       calibration for that module

       Statistics (attachment16)
       Rate spectra (attachment17)
       FEE temps (attachment18)
       Leakage currents written to sheet (attachment19)
       Tapeserver ~44MB/s
       Merger ~ 4.4M items/s
       
15.52 beam down R17_221, back at 15.58 R17_229

16.07 Beam down
       
16:20 Removed S480 files from /media/1e... and /media/SecondDrive
      Set merger to no output and stopped tapedata.
      Changed symbolic link of /TapeData to /media/1e.....
      Restarted tapedata and the merger with outputting to file R20
      Local DESPEC was made aware of this before carrying out and stopped the run.
      Beam back

17.12 beam down for a couple of minutes R20_90

17.40 System wide checks okay except ADC calibration:
       
       FEE64 module aida07 failed
       FEE64 module aida10 failed
       Calibration test result: Passed 10, Failed 2
       If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun 
       calibration for that module

       Statistics (attachment20)
       Rate spectra (attachment21)
       FEE temps (attachment22)
       Leakage currents written to sheet (attachment23)
       Tapeserver ~45MB/s
       Merger ~ 4.5M items/s

      
Attachment 1: Screenshot_from_2021-03-09_07-05-35.png  159 kB  | Hide | Hide all
Screenshot_from_2021-03-09_07-05-35.png
Attachment 2: Screenshot_from_2021-03-09_07-06-17.png  121 kB  | Hide | Hide all
Screenshot_from_2021-03-09_07-06-17.png
Attachment 3: Screenshot_from_2021-03-09_07-06-53.png  47 kB  | Hide | Hide all
Screenshot_from_2021-03-09_07-06-53.png
Attachment 4: Screenshot_from_2021-03-09_08-08-45_-_1.png  174 kB  Uploaded Tue Mar 9 08:25:44 2021  | Hide | Hide all
Screenshot_from_2021-03-09_08-08-45_-_1.png
Attachment 5: Screenshot_from_2021-03-09_08-24-06.png  190 kB  Uploaded Tue Mar 9 08:25:44 2021  | Hide | Hide all
Screenshot_from_2021-03-09_08-24-06.png
Attachment 6: Screenshot_from_2021-03-09_08-26-47.png  173 kB  Uploaded Tue Mar 9 08:27:19 2021  | Hide | Hide all
Screenshot_from_2021-03-09_08-26-47.png
Attachment 7: Screenshot_from_2021-03-09_08-44-17.png  234 kB  Uploaded Tue Mar 9 08:45:08 2021  | Hide | Hide all
Screenshot_from_2021-03-09_08-44-17.png
Attachment 8: 1130_Statistics.PNG  122 kB  Uploaded Tue Mar 9 10:46:46 2021  | Hide | Hide all
1130_Statistics.PNG
Attachment 9: 1130_SpectraRates.PNG  204 kB  Uploaded Tue Mar 9 10:46:50 2021  | Hide | Hide all
1130_SpectraRates.PNG
Attachment 10: 1130_FEETemps.PNG  157 kB  Uploaded Tue Mar 9 10:46:56 2021  | Hide | Hide all
1130_FEETemps.PNG
Attachment 11: 1130_LeakageCurrents.PNG  31 kB  Uploaded Tue Mar 9 10:46:59 2021  | Hide | Hide all
1130_LeakageCurrents.PNG
Attachment 12: 1330_Statistics.PNG  121 kB  Uploaded Tue Mar 9 12:31:15 2021  | Hide | Hide all
1330_Statistics.PNG
Attachment 13: 1330_SpectraRates.PNG  208 kB  Uploaded Tue Mar 9 12:31:20 2021  | Hide | Hide all
1330_SpectraRates.PNG
Attachment 14: 1330_FEETemps.PNG  158 kB  Uploaded Tue Mar 9 12:31:29 2021  | Hide | Hide all
1330_FEETemps.PNG
Attachment 15: 1330_LeakageCurrents.PNG  31 kB  Uploaded Tue Mar 9 12:31:33 2021  | Hide | Hide all
1330_LeakageCurrents.PNG
Attachment 16: 1540_Statistics.PNG  123 kB  Uploaded Tue Mar 9 14:44:37 2021  | Hide | Hide all
1540_Statistics.PNG
Attachment 17: 1540_SpectraRates.PNG  207 kB  Uploaded Tue Mar 9 14:44:40 2021  | Hide | Hide all
1540_SpectraRates.PNG
Attachment 18: 1540_FEETemps.PNG  157 kB  Uploaded Tue Mar 9 14:44:46 2021  | Hide | Hide all
1540_FEETemps.PNG
Attachment 19: 1540_LeakageCurrents.PNG  31 kB  Uploaded Tue Mar 9 14:44:49 2021  | Hide | Hide all
1540_LeakageCurrents.PNG
Attachment 20: 1730_Statistics.PNG  123 kB  Uploaded Tue Mar 9 16:29:47 2021  | Hide | Hide all
1730_Statistics.PNG
Attachment 21: 1730_SpectraRates.PNG  206 kB  Uploaded Tue Mar 9 16:29:57 2021  | Hide | Hide all
1730_SpectraRates.PNG
Attachment 22: 1730_FEETemps.PNG  158 kB  Uploaded Tue Mar 9 16:30:01 2021  | Hide | Hide all
1730_FEETemps.PNG
Attachment 23: 1730_LeakageCurrents.PNG  31 kB  Uploaded Tue Mar 9 16:30:06 2021  | Hide | Hide all
1730_LeakageCurrents.PNG
ELOG V3.1.4-unknown