08:00 System wide checks all ok *exctept aida07 and 10 on ADC calibration N.B. wrong date given to the screenshots by accident (It's early) Statistics - attachment 1 FEE temperatures (AIDA10 unavailable) - attachment 2 FEE temperature - attachment 3 Bias and leakage currents ok - attachment 4 08:34 The FRS stopped receiving ions. AIDA crashed simultaneously with it. Have now recovered AIDA daq - Looking at the messages log AIDA04 restarted itself. Restarted but no stats in aida04 It did not recover from a reset Telnet in and did a reboot command 09:10 Finally recovered issue was it was not linking to merger There is an options issue with aida12. The ASIC settings had become undefined and there are no histograms Manually set the ASIC settings for aida12. Rates look as expected after Will try to reset once beam is back 10:12 Problem with the DAQ so stopping AIDA while they work will switch MBS relay out to new version Analysis of R30_21 looks fine 10:38 System wide checks ok Statistics - attachment 5 Temperature - attachment 6 Bias and leakage - attachment 7 12.10 (LS) System wide checks all okay, no fails Statistics (attachment8) Rate spectra (attachment9) FEE temps (attament10) Leakage currents written to sheet (attachment11) Merger ~45M items/s Tapeserver ~14MB/s 13.45 no beam (around file R30_98) 14.00 System wide checks all okay, no fails Statistics (attachment12) FEE temps (attament13) Leakage currents written to sheet (attachment14) Merger ~44M items/s Tapeserver ~14MB/s Beam still down 14.11 beam back aida file R30_112 14.13 beam back down, back at 14.16 14.20 no beam 14.23 notice some timestamp error in ucesb 37 minutes ago (about R30_102) no errors appeared on the MBS relay terminal, double by analysing R30_101,102,103 no timewarps beam is back but low intensity at the moment 14.46 beam looks to be back at a higher intensity now R30_127 (attachment15) 16.00 System wide checks all okay, no fails Statistics (attachment16) Rate spectra (attachment17) FEE temps (attament18) Leakage currents written to sheet (attachment19) Merger ~45M items/s Tapeserver ~14MB/s 18.00 System wide checks all okay, no fails Statistics (attachment20) Rate spectra (attachment21) FEE temps (attament22) Leakage currents written to sheet (attachment23) Merger ~45M items/s Tapeserver ~15MB/s bunch of timewarp errors in ucesb, no errors in MBS relay terminal though now see error in MBS relay! "Warning: At least one MIDAS block missed in relay" Warning was set up by NH and OH to detect if the LSB of the first ADC data item in a block is less than the LAST LSB of the previous data block. It then iterates the info code 4 and if needed 5 stored before resetting the LSB stored. It triggered 63 times. I have checked all the files in the vicinity and there are no timewarps in the MIDAS data visible to TD's analyser 19:10 MBS DAQ stopped to allow FRS tests 19:38 MBS DAQ is back 20:15 Aida07 fails FPGA check Base Current Difference aida07 fault 0x0 : 0x1 : 1 FPGA Timestamp error counter test result: Passed 11, Failed 1 If any of these counts are reported as in error The ASIC readout system has detected a timeslip. That is the timestamp read from the time FIFO is not younger than the last All other system wide checks ok Statistics - attachment 24 (Again ignore the year in the filename) Temperatures - attachment 25 Bias and leakage currents - 26 21:36 They are resetting the time sorter due to FATIMA issues 22:38 System wide checks error on WR in addition to the previous FPGA error Base Current Difference aida05 fault 0x5cc9 : 0x5cca : 1 aida06 fault 0xde76 : 0xde77 : 1 aida07 fault 0xa566 : 0xa567 : 1 aida08 fault 0x6ab0 : 0x6ab1 : 1 White Rabbit error counter test result: Passed 8, Failed 4 Statistics - attachment 27 Temperature - attachment 28 Bias and leakage current - attachment 29 23:02 We still see timewarp errors in the ucesb. With our changes to the relay we can confirm that the WR headers in the MBS relay are time ordered. The issue must be downstream in the MBS chain.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown