AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
DESPEC
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:38:13 2025
Author
*
:
Subject
*
:
00:08 DAQ continues ok - writing to file R46_221 ASIC settings 2019Dec19-16.19.51 DSSSD#1 slow comparator 0xa DSSSD#2 slow comparator 0xa DSSSD#3 slow comparator 0xd BNC PB-5 Pulser Amplitude1.0V Attenuation x1 Frequency 2Hz tau_d 1ms - polarity Delay 250ns, tail pulse 00:09 system wide checks: FEE64 module aida09 global clocks failed, 6 Clock status test result: Passed 11, Failed 1 Understand status as follows Status bit 3 : firmware PLL that creates clocks from external clock not locked Status bit 2 : always logic '1' Status bit 1 : LMK3200(2) PLL and clock distribution chip not locked to external clock Status bit 0 : LMK3200(1) PLL and clock distribution chip not locked to external clock If all these bits are not set then the operation of the firmware is unreliable FEE64 module aida09 failed Calibration test result: Passed 11, Failed 1 If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module Base Current Difference aida07 fault 0x82a0 : 0x82a4 : 4 White Rabbit error counter test result: Passed 11, Failed 1 Understand the status reports as follows:- Status bit 3 : White Rabbit decoder detected an error in the received data Status bit 2 : Firmware registered WR error, no reload of Timestamp Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR Base Current Difference aida07 fault 0x2 : 0x3 : 1 FPGA Timestamp error counter test result: Passed 11, Failed 1 If any of these counts are reported as in error The ASIC readout system has detected a timeslip. That is the timestamp read from the time FIFO is not younger than the last Returned 0 0 0 0 0 0 0 0 0 0 0 0 Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k aida01 : 11 6 2 5 1 3 2 2 3 4 10 : 54492 aida02 : 12 7 3 4 3 3 3 2 3 3 6 : 36440 aida03 : 4 4 2 4 2 3 2 2 3 3 6 : 36048 aida04 : 18 9 4 2 1 3 2 4 1 4 15 : 73936 aida05 : 31 11 8 7 6 4 2 18 7 4 7 : 55220 aida06 : 36 8 18 4 4 2 1 4 3 2 5 : 31088 aida07 : 26 7 4 3 1 2 1 3 3 3 6 : 36224 aida08 : 25 12 5 4 4 3 2 3 3 3 6 : 36884 aida09 : 2 9 4 2 2 2 2 3 3 3 6 : 36432 aida10 : 11 3 4 6 4 3 1 3 3 3 6 : 36548 aida11 : 21 8 5 0 1 3 3 3 2 3 6 : 35748 aida12 : 10 6 6 2 4 4 1 3 3 3 6 : 36600 00:14 FEE64 Temperatures ok - attachment 1 Good event statistics ok - attachment 2 Detector bias/leakage currents ok - attachment 3 00:17 Merger ok - 4.4M items/s TapeServer ok - 14 MB/s 01:30 beam off 01:31 beam back 02:19 system wide checks same as entry at 00:09, *except* Base Current Difference aida07 fault 0x82a0 : 0x82a5 : 5 White Rabbit error counter test result: Passed 11, Failed 1 02:22 FEE64 Temperatures ok - attachment 4 Good event statistics ok - attachment 5 Detector bias/leakage currents ok - attachment 6 02:30 Merger ok - 4.4M items/s TapeServer ok - 14 MB/s no further bad timestamp errors in NewMerger terminal 02:40 ... burst of bad timestamp errors in NewMerger terminal - attachment 7 02:50 ... and sure enough lose connection to aida07 after checking stats DAQ stop, Merger/TapeServer closed telnet aida07 -> sent reboot command mounted ok, reset DAQ, TapeService and Merge restarted DATA forwarding to MBS all looks to be ok now -> writing to R56 03:09 system wide checks: FEE64 module aida09 global clocks failed, 6 Clock status test result: Passed 11, Failed 1 Understand status as follows Status bit 3 : firmware PLL that creates clocks from external clock not locked Status bit 2 : always logic '1' Status bit 1 : LMK3200(2) PLL and clock distribution chip not locked to external clock Status bit 0 : LMK3200(1) PLL and clock distribution chip not locked to external clock If all these bits are not set then the operation of the firmware is unreliable FEE64 module aida07 failed FEE64 module aida09 failed Calibration test result: Passed 10, Failed 2 If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module Base Current Difference aida07 fault 0x2 : 0x5 : 3 FPGA Timestamp error counter test result: Passed 11, Failed 1 If any of these counts are reported as in error The ASIC readout system has detected a timeslip. That is the timestamp read from the time FIFO is not younger than the last Returned 0 0 0 0 0 0 0 0 0 0 0 0 Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k aida01 : 13 5 3 7 2 2 2 2 3 4 10 : 54508 aida02 : 2 7 3 2 2 3 1 4 3 3 6 : 36784 aida03 : 8 8 1 3 2 3 1 3 3 3 6 : 36304 aida04 : 20 9 2 3 0 3 2 4 1 4 15 : 73880 aida05 : 51 74 70 54 53 49 22 18 7 4 7 : 72188 aida06 : 15 15 3 9 1 2 2 4 3 2 5 : 31044 aida07 : 24 6 2 3 3 4 2 3 2 3 7 : 39888 aida08 : 19 15 1 2 1 3 1 4 3 3 6 : 36820 aida09 : 18 4 2 7 3 4 1 3 3 3 6 : 36648 aida10 : 20 7 1 1 1 3 3 2 3 3 6 : 36216 aida11 : 25 7 5 3 4 2 1 4 2 3 6 : 35916 aida12 : 3 3 2 2 3 2 3 2 3 3 6 : 36164 03:18 FEE64 Temperatures ok - attachment 8 Good event statistics ok - attachment 9 Detector bias/leakage currents ok - attachment 10 Merger ok - 4.4M items/s TapeServer ok - 14 MB/s 03:29 more bad timestamp error messages - attachment 11 03:52 analyser output on R56_35 - attachment 12 no timewarps 03:53 DAQ continues ok, writing to file R56_41 05:18 system wide checks: same as entry at 03:08, *but* with additional WR decoder status error Base Current Difference aida07 fault 0x8c74 : 0x8c77 : 3 White Rabbit error counter test result: Passed 11, Failed 1 Understand the status reports as follows:- Status bit 3 : White Rabbit decoder detected an error in the received data Status bit 2 : Firmware registered WR error, no reload of Timestamp Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR 05:19 FEE64 Temperatures ok - attachment 14 Good event statistics ok - attachment 13 Detector bias/leakage currents ok - attachment 15 Merger ok - 4.4M items/s TapeServer ok - 15 MB/s 05:25 rate spectra - attachment 16 05:33 AIDA implant XY hit patterns - attachments 17/18/19 05:56 BuTIS interface control set to 0x3 at 04.52 UTC 07:06 system wide checks - same error messages as entry at 05:18 07:08 FEE64 Temperatures ok - attachment 20 good event statistics ok - attachment 21 detector bias/leakage currents ok - attachment 22 Merger ok - 4.3M items/s TapeServer ok - 15 MB/s 07:22 no bad timestamp errors since 02:30 UTC
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown