12:37 DAQ found crashed. Had crashed at some time following 7:50am following previous statistics update Unable to recover the FEEs so forced to power cycle Following power cycle statistics much improved from yesterday. In the waveforms the lower frequency component that was prevalent yesterday is no longer visible. The waveforms are not perfect by any means though Also note that following an ASIC synchronisation all of the FEEs lose ADC calibration and must be manually recalibrated. 16.42 UTC+1 per FEE64 1.8.W spectra 20us FSR attachments 7 & 8 200us FSR attachments 9 & 10 2ms FSR attachments 11 & 12 20ms FSR attachments 15 & 16 rate spectra attachment 13 good events statistics attachment 14