Every 30 minutes:
- Reload statistics (Web browser tab screen 1, workspace 2)
- Are all FEEs still showing a rate?
- If one shows 0 after multiple reloads Call Oscar or Tom.
- Options database monitor (Top middle terminal screen 2, workspace 2)
- Has the message changed since the last check?
- If so copy the message and place in elog
- Do the ucesb scalers make sense? (Web browser, screen 2, workspace 4)
- If one DSSD is reporting kHz of implants when the others are much less it is likely an ASIC getting stuck.
- Perform and ASIC check (ASIC control tab, web browser, screen 1, workspace 2)
- Ensure "Act on all FEE" and "Act on all asic" selected
- Click on drop down menu in the bottom of the screen and select check ASIC control
- It will take a minute or so be patient (MIDAS can only respond to one command at once so don't try to do anything else)
- A pop up will appear check that all options say ok
- Has the implant rate gone to a more normal amount?
- If not feel free to call
Every two hours:
- Take a screenshot of the statistics page (Web browser tab screen 1, workspace 2)
- Compare to the previous screenshot to check if anything has drastically changed
- Take a screenshot of the temperatures (Web browser tab screen 1, workspace 2)
- Do they all appear stable?
- Take a screenshot of the bias and leakage currents - (Top left terminal, screen 2, workspace 2)
- Perform the five system wide checks (Web browser tab screen 1, workspace 2)
- Make a note in the elog of which tests are successful
- If failed copy the text from the white box into the elog and make a note of it
- Enter the screenshots into the elog
- Update the leakage current spreadsheet (Web browser, screen 2, workspace 4) |