Subject
*
:
12.18 DAQ continues file NULL/R30_490 ASIC settings 2019Dec19-16.19.51 slow comparator 0x64 -> 0xa BNC PB-5 amplitude 2V attenuation 1x decay time 1ms frequency 2Hz 12.22 all histograms zero'd c. 12.30 219Rn setting 12.35 analysis of R30_490 - see attachment 1 13.15 system wide checks Clock status test result: Passed 12, Failed 0 Understand status as follows Status bit 3 : firmware PLL that creates clocks from external clock not locked Status bit 2 : always logic '1' Status bit 1 : LMK3200(2) PLL and clock distribution chip not locked to external clock Status bit 0 : LMK3200(1) PLL and clock distribution chip not locked to external clock If all these bits are not set then the operation of the firmware is unreliable FEE64 module aida06 failed FEE64 module aida07 failed FEE64 module aida10 failed Calibration test result: Passed 9, Failed 3 If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module Base Current Difference aida01 fault 0x7686 : 0x768a : 4 aida02 fault 0x941d : 0x9421 : 4 aida03 fault 0x7cd7 : 0x7cdb : 4 aida04 fault 0xb86d : 0xb871 : 4 aida05 fault 0x1a59 : 0x1a5f : 6 aida06 fault 0x4f45 : 0x4f4b : 6 aida07 fault 0x3bfc : 0x3c04 : 8 aida08 fault 0xc7ce : 0xc7d4 : 6 aida09 fault 0xb33b : 0xb33c : 1 White Rabbit error counter test result: Passed 3, Failed 9 Understand the status reports as follows:- Status bit 3 : White Rabbit decoder detected an error in the received data Status bit 2 : Firmware registered WR error, no reload of Timestamp Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR Base Current Difference aida12 fault 0xa : 0xb : 1 FPGA Timestamp error counter test result: Passed 11, Failed 1 If any of these counts are reported as in error The ASIC readout system has detected a timeslip. That is the timestamp read from the time FIFO is not younger than the last Returned 0 0 0 0 0 0 0 0 0 0 0 0 Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k aida01 : 23 10 3 1 1 2 1 3 3 3 6 : 36156 aida02 : 2 11 7 4 2 2 2 4 2 3 6 : 36048 aida03 : 21 8 6 4 5 4 3 3 2 3 6 : 36276 aida04 : 19 11 14 3 2 3 2 4 2 3 6 : 36324 aida05 : 25 4 5 4 4 2 1 3 2 4 6 : 37460 aida06 : 13 9 15 1 3 5 1 3 3 3 6 : 36812 aida07 : 19 10 6 1 3 3 2 2 4 3 6 : 37212 aida08 : 23 6 4 2 1 1 3 4 2 3 6 : 36044 aida09 : 11 5 5 1 2 4 3 3 2 3 6 : 35908 aida10 : 14 5 6 5 3 1 3 3 2 3 6 : 35744 aida11 : 16 5 3 0 3 3 1 4 2 3 6 : 35800 aida12 : 12 10 0 2 4 4 1 3 3 3 6 : 36544 Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same FEE : aida01 => Options file size is 1025 Last changed Sat Apr 17 06:14:30 CEST 2021 FEE : aida02 => Options file size is 1014 Last changed Fri Apr 16 00:56:20 CEST 2021 FEE : aida03 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 FEE : aida04 => Options file size is 1025 Last changed Sat Apr 17 06:07:36 CEST 2021 FEE : aida05 => Options file size is 1025 Last changed Fri Apr 16 00:53:25 CEST 2021 FEE : aida06 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 FEE : aida07 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 FEE : aida08 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 FEE : aida09 => Options file size is 1014 Last changed Wed Apr 14 21:52:05 CEST 2021 FEE : aida10 => Options file size is 1014 Last changed Wed Apr 14 21:52:06 CEST 2021 FEE : aida11 => Options file size is 1014 Last changed Wed Apr 14 21:52:05 CEST 2021 FEE : aida12 => Options file size is 1025 Last changed Wed Apr 14 21:58:54 CEST 2021 *no faults detected by ~/oh/OptionsCheck.py 13.10 Detector biases & leakage currents OK - see attachment 2 Statistics - good events, adc data, disc data, info code 4 & 5, pause, resume, correlation info - attachments 3-12 per FEE64 rate spectra - attachments 13-14 1.8.L spectra - attachments 15-18 pulser peak widths 1 80 2 113 3 308 4 105 5 50 6 91 7 61 8 90 9 200 10 133 11 187 12 107 1.8.H spectra - attachments 19-20 1.8.W spectra - attachments 21-22 ucesb - attachment 23 implant rates DSSSD#1-3 to c. 1kHz grafana - AIDA DSSSD leakage currents for previous 2 days - attachment 24 merger & merger/tape server/mbs data tranfser - attachment 25 no recent merger warning/error messages 13.30 225At setting
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown