> 12.18 DAQ continues file NULL/R30_490 > > ASIC settings 2019Dec19-16.19.51 > slow comparator 0x64 -> 0xa > > BNC PB-5 > amplitude 2V > attenuation 1x > decay time 1ms > frequency 2Hz > > 12.22 all histograms zero'd > > c. 12.30 219Rn setting > > 12.35 analysis of R30_490 - see attachment 1 > > 13.15 system wide checks > > Clock status test result: Passed 12, Failed 0 > Understand status as follows > Status bit 3 : firmware PLL that creates clocks from external clock not locked > Status bit 2 : always logic '1' > Status bit 1 : LMK3200(2) PLL and clock distribution chip not locked to external clock > Status bit 0 : LMK3200(1) PLL and clock distribution chip not locked to external clock > If all these bits are not set then the operation of the firmware is unreliable > > FEE64 module aida06 failed > FEE64 module aida07 failed > FEE64 module aida10 failed > Calibration test result: Passed 9, Failed 3 > If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module > > Base Current Difference > aida01 fault 0x7686 : 0x768a : 4 > aida02 fault 0x941d : 0x9421 : 4 > aida03 fault 0x7cd7 : 0x7cdb : 4 > aida04 fault 0xb86d : 0xb871 : 4 > aida05 fault 0x1a59 : 0x1a5f : 6 > aida06 fault 0x4f45 : 0x4f4b : 6 > aida07 fault 0x3bfc : 0x3c04 : 8 > aida08 fault 0xc7ce : 0xc7d4 : 6 > aida09 fault 0xb33b : 0xb33c : 1 > White Rabbit error counter test result: Passed 3, Failed 9 > Understand the status reports as follows:- > Status bit 3 : White Rabbit decoder detected an error in the received data > Status bit 2 : Firmware registered WR error, no reload of Timestamp > Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR > > Base Current Difference > aida12 fault 0xa : 0xb : 1 > FPGA Timestamp error counter test result: Passed 11, Failed 1 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > > Returned 0 0 0 0 0 0 0 0 0 0 0 0 > Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k > aida01 : 23 10 3 1 1 2 1 3 3 3 6 : 36156 > aida02 : 2 11 7 4 2 2 2 4 2 3 6 : 36048 > aida03 : 21 8 6 4 5 4 3 3 2 3 6 : 36276 > aida04 : 19 11 14 3 2 3 2 4 2 3 6 : 36324 > aida05 : 25 4 5 4 4 2 1 3 2 4 6 : 37460 > aida06 : 13 9 15 1 3 5 1 3 3 3 6 : 36812 > aida07 : 19 10 6 1 3 3 2 2 4 3 6 : 37212 > aida08 : 23 6 4 2 1 1 3 4 2 3 6 : 36044 > aida09 : 11 5 5 1 2 4 3 3 2 3 6 : 35908 > aida10 : 14 5 6 5 3 1 3 3 2 3 6 : 35744 > aida11 : 16 5 3 0 3 3 1 4 2 3 6 : 35800 > aida12 : 12 10 0 2 4 4 1 3 3 3 6 : 36544 > > Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same > > FEE : aida01 => Options file size is 1025 Last changed Sat Apr 17 06:14:30 CEST 2021 > FEE : aida02 => Options file size is 1014 Last changed Fri Apr 16 00:56:20 CEST 2021 > FEE : aida03 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 > FEE : aida04 => Options file size is 1025 Last changed Sat Apr 17 06:07:36 CEST 2021 > FEE : aida05 => Options file size is 1025 Last changed Fri Apr 16 00:53:25 CEST 2021 > FEE : aida06 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 > FEE : aida07 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 > FEE : aida08 => Options file size is 1014 Last changed Wed Apr 14 21:52:04 CEST 2021 > FEE : aida09 => Options file size is 1014 Last changed Wed Apr 14 21:52:05 CEST 2021 > FEE : aida10 => Options file size is 1014 Last changed Wed Apr 14 21:52:06 CEST 2021 > FEE : aida11 => Options file size is 1014 Last changed Wed Apr 14 21:52:05 CEST 2021 > FEE : aida12 => Options file size is 1025 Last changed Wed Apr 14 21:58:54 CEST 2021 > > *no faults detected by ~/oh/OptionsCheck.py > > 13.10 Detector biases & leakage currents OK - see attachment 2 > Statistics - good events, adc data, disc data, info code 4 & 5, pause, resume, correlation info - attachments 3-12 > per FEE64 rate spectra - attachments 13-14 > 1.8.L spectra - attachments 15-18 > > pulser peak widths > 1 80 > 2 113 > 3 308 > 4 105 > 5 50 > 6 91 > 7 61 > 8 90 > 9 200 > 10 133 > 11 187 > 12 107 > > 1.8.H spectra - attachments 19-20 > 1.8.W spectra - attachments 21-22 > ucesb - attachment 23 > implant rates DSSSD#1-3 to c. 1kHz > grafana - AIDA DSSSD leakage currents for previous 2 days - attachment 24 > merger & merger/tape server/mbs data tranfser - attachment 25 > no recent merger warning/error messages > > 13.30 225At setting
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown