AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
DESPEC
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:26:55 2025
Author
*
:
Subject
*
:
> 00:00 - CA takes over > > 00:15 - stats/database/ucesb ok - attachment 1 > > - another burst of bad timestamp error messages in NewMerger terminal - but all FEE64 still ok - attachment 2 > > - Merger/TapeService ok > > 00:21 - beam still off while UNILAC having problems > > 00:26 - beam is back - rate spectra - attachment 3 > > 00:32 - ucesb following beam return - attachment 4 > > - implant rates reaching highs of ~1kHz > > 00:35 - Grafana leakage current monitor last 6 hours - attachment 5 > > 01:00 *all* system wide checks ok > > stats ok - attachment 6 > > temperatures ok - attachment 7 > > detector bias / leakage currents ok - attachment 8 > > db check ok / ucesb ok > > still observe periodic bursts of bad timestamp errors in NewMerger terminal - FEE64s still linked with merger ok > > 01:30 AIDA crashes just as I make check, most FEE64 lost connection -> powercycle and restart MIDAS > > 01:53 AIDA reset completed - writing to file NULL/R48 > > 01:56 all system wide checks ok *except* > > FPGA error counter > > Base Current Difference > aida12 fault 0x0 : 0x1 : 1 > FPGA Timestamp error counter test result: Passed 11, Failed 1 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > ADC calibration > > FEE64 module aida04 failed > FEE64 module aida05 failed > Calibration test result: Passed 10, Failed 2 > > If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module > > > 02:01 good event statistics ok - attachment 9 > > temperatures ok - attachment 10 > > detector bias / leakage currents ok - attachment 11 > > db check / ucesb ok > > 02:20 beam stop > > 02:21 beam back > > 02:30 stats/ucesb/db checks all ok > > 03:00 stats/ucesb/db checks all ok - attachment 12 > > 03:30 stats/ucesb/db checks all ok > > 04:00 system wide checks ok, except; > > ADC calibration > > FEE64 module aida04 failed > FEE64 module aida05 failed > Calibration test result: Passed 10, Failed 2 > > If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module > > FPGA errors > > Base Current Difference > aida12 fault 0x0 : 0x9 : 9 > FPGA Timestamp error counter test result: Passed 11, Failed 1 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > 04:03 beam off briefly > > 04:05 good event statistics ok - attachment 13 > > 04:07 beam back > > temperatures ok - attachment 14 > > bias / leakage currents ok - attachment 15 > > db check / ucesb ok - attachment 16 > > implant rates in AIDA peaking at ~1.5kHz > > 04:30 stats/ucesb/db checks all ok > > 04:48 no beam > > 04:58 beam back > > 05:00 stats/ucesb/db checks all ok - attachment 17 > > 05:30 stats/ucesb/db checks all ok > > 06:00 system wide checks ok, except; > > ADC calibration > > FEE64 module aida04 failed > FEE64 module aida05 failed > Calibration test result: Passed 10, Failed 2 > > If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module > > FPGA errors > > Base Current Difference > aida12 fault 0x0 : 0x9 : 9 > FPGA Timestamp error counter test result: Passed 11, Failed 1 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > FEE64 Linux Memory Info > > Returned 0 0 0 0 0 0 0 0 0 0 0 0 > Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k > aida01 : 5 5 3 3 2 3 2 3 2 3 7 : 39628 > aida02 : 22 11 3 0 2 3 2 3 2 3 7 : 39648 > aida03 : 20 10 1 1 2 2 1 4 2 3 7 : 39760 > aida04 : 17 10 2 2 3 3 2 3 2 3 7 : 39732 > aida05 : 1 8 3 2 3 2 2 3 3 3 7 : 40564 > aida06 : 5 6 2 3 2 2 3 3 2 3 7 : 39748 > aida07 : 18 4 7 0 1 3 1 4 2 3 7 : 39832 > aida08 : 22 10 3 3 2 2 3 3 2 3 7 : 39864 > aida09 : 3 6 2 2 0 3 1 4 2 3 7 : 39708 > aida10 : 2 4 3 2 1 2 2 3 2 3 7 : 39384 > aida11 : 20 8 3 1 1 3 3 2 2 3 7 : 39328 > aida12 : 16 6 3 1 0 3 2 3 2 3 7 : 39488 > > 06:02 good event statistics ok - attachment 18 > > FEE64 temperatures ok - attachment 19 > > detector bias / leakage currents ok - attachment 20 > > 06:06 db check and ucesb ok - attachment 21 > > NewMerger terminal hasn't flagged up any more errors since ~ 03:00 > > 06:30 stats/ucesb/db checks all ok > > DESPEC restarts timesorter > > 07:00 stats/ucesb/db checks all ok > > 07:30 stats/ucesb/db checks all ok - attachment 22 > > grafana leakage currents last 1 hour - attachment 23 > > > > > > > > > > > >
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown