> 01:50 Beam on > The leakage current and the voltages been monitered every half an hour and logged in the excel sheet, looks decreasing. > Tempetratures OK > > Rates OK > > Attachment 1 Voltages > > Atachment 2 Rates > > Atachment 3 Temperatures > > Attachment 4 ucesb rates less than 1 kHz > > > System wide check are ok except: > > Base Current Difference > aida05 fault 0x36ca : 0x36ce : 4 > White Rabbit error counter test result: Passed 15, Failed 1 > > Understand the status reports as follows: > Status bit 3 : White Rabbit decoder detected an error in the received data > Status bit 2 : Firmware registered WR error, no reload of Timestamp > Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR > > Base Current Difference > aida13 fault 0xa : 0xe9 : 223 > FPGA Timestamp error counter test result: Passed 15, Failed 1 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > > Returned 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 > Mem(KB) : 4 8 16 32 64 128 256 512 1k 2k 4k > aida01 : 0 5 3 0 1 4 3 3 3 3 6 : 36760 > aida02 : 7 9 0 2 2 4 2 3 3 3 6 : 36644 > aida03 : 1 3 2 1 2 1 2 3 3 3 6 : 36188 > aida04 : 3 1 2 0 2 3 2 3 3 3 6 : 36404 > aida05 : 20 9 3 2 2 3 2 2 3 3 6 : 36104 > aida06 : 4 10 0 2 2 4 2 2 3 3 6 : 36128 > aida07 : 3 1 2 1 3 3 2 3 3 3 6 : 36500 > aida08 : 2 4 3 2 3 4 2 3 2 3 6 : 35672 > aida09 : 1 6 3 3 1 4 2 3 2 3 6 : 35588 > aida10 : 5 6 4 2 1 3 2 3 2 3 6 : 35460 > aida11 : 23 8 2 2 2 3 3 4 2 3 6 : 36348 > aida12 : 8 4 2 2 2 3 2 4 2 3 6 : 36000 > aida13 : 2 5 3 1 2 4 3 3 2 3 6 : 35840 > aida14 : 3 6 2 2 2 3 2 4 2 3 6 : 35996 > aida15 : 2 4 3 3 0 4 1 3 3 3 6 : 36280 > aida16 : 7 7 5 1 3 4 2 3 2 3 6 : 35716 > > > > <strong>05:00 OH Took over at 04:00</strong> > > System wide checks ok except > > Base Current Difference > aida05 fault 0x36ca : 0x36d0 : 6 > White Rabbit error counter test result: Passed 15, Failed 1 > > Understand the status reports as follows:- > Status bit 3 : White Rabbit decoder detected an error in the received data > Status bit 2 : Firmware registered WR error, no reload of Timestamp > Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR > > > Base Current Difference > aida05 fault 0x0 : 0x1 : 1 > aida13 fault 0xa : 0xe9 : 223 > FPGA Timestamp error counter test result: Passed 14, Failed 2 > If any of these counts are reported as in error > The ASIC readout system has detected a timeslip. > That is the timestamp read from the time FIFO is not younger than the last > > > > 05:41 AIDA 05 has dropped out. Will restart the system > > 05:58 DAQ recovered from powercycle > p+n strips at 0xa > n+n strips at 0x20 > ADC control register at 0xFF > All waveforms turned off in LED > > Statistics - attachment 5 > Correlation scaler in FEE 3 and 4 are mostly tracking 1:1 > > 06:34 Local users have been unable to recover MBS > And have been unable to contact local experts > > 07:22 Bias and leakage currents ok - attachment 6 > Stats attachment -7
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown