Entry time:
Sat Mar 29 11:37:48 2025
Author
*
:
Subject
*
:
<p><strong>16:25</strong></p> <p>Informed at shift handover that there has been no beam.</p> <p>Statistics - See attachment 1</p> <p>Temperatures - See attachment 2</p> <p>Bias & Leakage currents - See attachment 3</p> <p><strong>System Wide checks - All passed, EXCEPT:</strong></p> <p><strong>ADC Calibration</strong></p> <p> <br /> FEE64 module aida01 failed<br /> FEE64 module aida02 failed<br /> FEE64 module aida03 failed<br /> FEE64 module aida04 failed<br /> FEE64 module aida05 failed<br /> FEE64 module aida06 failed<br /> FEE64 module aida07 failed<br /> FEE64 module aida08 failed<br /> FEE64 module aida09 failed<br /> FEE64 module aida10 failed<br /> FEE64 module aida11 failed<br /> FEE64 module aida12 failed<br /> FEE64 module aida13 failed<br /> FEE64 module aida14 failed<br /> FEE64 module aida15 failed<br /> FEE64 module aida16 failed<br /> Calibration test result: Passed 0, Failed 16</p> <p>If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module</p> <p> </p> <p><strong>White Rabbit decoder status:</strong></p> <p> <br /> Base Current Difference<br /> aida05 fault 0x4da : 0x4dd : 3 <br /> White Rabbit error counter test result: Passed 15, Failed 1</p> <p>Understand the status reports as follows:-<br /> Status bit 3 : White Rabbit decoder detected an error in the received data<br /> Status bit 2 : Firmware registered WR error, no reload of Timestamp<br /> Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR</p> <p> </p> <p><strong>18:00</strong></p> <p>Usecb scalars now showing DSSD implant rates.</p> <p>Statistics - See attachment 4</p> <p>Temperatures - See attachment 5</p> <p>Bias & Leakage currents - See attachment 6</p> <p><strong>System Wide checks - All passed, EXCEPT:</strong></p> <p><strong>ADC Calibration</strong></p> <p> <br /> FEE64 module aida01 failed<br /> FEE64 module aida02 failed<br /> FEE64 module aida03 failed<br /> FEE64 module aida04 failed<br /> FEE64 module aida05 failed<br /> FEE64 module aida06 failed<br /> FEE64 module aida07 failed<br /> FEE64 module aida08 failed<br /> FEE64 module aida09 failed<br /> FEE64 module aida10 failed<br /> FEE64 module aida11 failed<br /> FEE64 module aida12 failed<br /> FEE64 module aida13 failed<br /> FEE64 module aida14 failed<br /> FEE64 module aida15 failed<br /> FEE64 module aida16 failed<br /> Calibration test result: Passed 0, Failed 16</p> <p>If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module</p> <p><strong>White rabbit decoder status</strong></p> <p> <br /> Base Current Difference<br /> aida05 fault 0x4da : 0x4e1 : 7 <br /> White Rabbit error counter test result: Passed 15, Failed 1</p> <p>Understand the status reports as follows:-<br /> Status bit 3 : White Rabbit decoder detected an error in the received data<br /> Status bit 2 : Firmware registered WR error, no reload of Timestamp<br /> Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WRx</p> <p> </p> <p><strong>19:45</strong></p> <p>Usecb scalars have continued to show DSSD implant rates since the last recorded elog check.</p> <p>Statistics - See attachment 7</p> <p>Temperatures - See attachment 8</p> <p>Bias & Leakage currents - See attachment 9</p> <p><strong>System Wide checks - All passed, EXCEPT:</strong></p> <p><strong>ADC Calibration:</strong></p> <p> <br /> FEE64 module aida01 failed<br /> FEE64 module aida02 failed<br /> FEE64 module aida03 failed<br /> FEE64 module aida04 failed<br /> FEE64 module aida05 failed<br /> FEE64 module aida06 failed<br /> FEE64 module aida07 failed<br /> FEE64 module aida08 failed<br /> FEE64 module aida09 failed<br /> FEE64 module aida10 failed<br /> FEE64 module aida11 failed<br /> FEE64 module aida12 failed<br /> FEE64 module aida13 failed<br /> FEE64 module aida14 failed<br /> FEE64 module aida15 failed<br /> FEE64 module aida16 failed<br /> Calibration test result: Passed 0, Failed 16</p> <p>If any modules fail calibration , check the clock status and open the FADC Align and Control browser page to rerun calibration for that module</p> <p><br /> <strong>White Rabbit decoder status:</strong></p> <p> Base Current Difference<br /> aida05 fault 0x4da : 0x4e1 : 7 <br /> White Rabbit error counter test result: Passed 15, Failed 1</p> <p>Understand the status reports as follows:-<br /> Status bit 3 : White Rabbit decoder detected an error in the received data<br /> Status bit 2 : Firmware registered WR error, no reload of Timestamp<br /> Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR</p> <p> </p> <p>19:50 - Just as completing checks, notced usesb rates not showing DSSD implants again for several minutes</p> <p>19:55 - Beam now back again - DSSD implants showing</p> <p> </p> <p> </p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown