AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
DESPEC
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:26:37 2025
Author
*
:
Subject
*
:
> 08:00 OH Takes over for CA > Thresholds 0xc for p+n and 0x19 for n+n ASICs 1-3 and 0x64 for n+nASIC4 > > PULSER SETTINGS > --------------------------- > Pulse is ON > Positive Tail Pulse > Trigger Source is Internal Clock > Trigger Threshold is 3.5 > Amplitude : 2.0 Volts > Rep Rate : 2.0 hZ > Delay : 250.0 ns > Fall Time : 1 ms > Attenuation : 1 > Display is : Volts > Equivalent keV is : 200.0 > Ramp Start at 0.01 Volts > Ramp Stop at 9.99 Volts > Ramp Start at 1.0 keV > Ramp Stop at 999.0 keV > Ramp Time is 60 seconds > # Ramp Cycles is 1 > > Max average dead time in R14_586 3.2% which is 9.6% on spill > Stable from yesterday > > 10:02 System wide checks. All ok expect WR > > Base Current Difference > aida05 fault 0x500 : 0x554 : 84 > White Rabbit error counter test result: Passed 15, Failed 1 > > Understand the status reports as follows:- > Status bit 3 : White Rabbit decoder detected an error in the received data > Status bit 2 : Firmware registered WR error, no reload of Timestamp > Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR > > Statistics - Attachment 1 > Temp - attachment 2 > Bias and leakage currents ok - Attachment 3 > > > 11:17 A new run was started as the microspill has been changed. I believe to optimise FRS deadtime. > 11:45 They are still working on it > > 12:05 Beam off for a bit while they optimise spill > > 12:15 System wide checks ok expect WR > > Base Current Difference > aida05 fault 0x500 : 0x567 : 103 > White Rabbit error counter test result: Passed 15, Failed 1 > > Understand the status reports as follows:- > Status bit 3 : White Rabbit decoder detected an error in the received data > Status bit 2 : Firmware registered WR error, no reload of Timestamp > Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR > > Statistics - Attachment 4 > Temp - Attachment 5 > Bias - Attachment 6 > > 13:11 Magda has said that the changes to the spill structure only gained them a few percent in dead time > Further changes could be done, but would take at least two hours > > 13:19 Dead time following the current spill changes > R14_648 R14_649 R14_650 R14_651 Sum DT (S) Avergage DT (%) On Spill DT (%) > FEE 244.823 252.168 247.155 240.421 984.567 > 0 0.063 0.025 0.105 0.096 0.289 0.029353005 0.088059015 > 1 3.981 4.907 4.17 2.484 15.542 1.578561947 4.73568584 > 2 0.01 0 0.121 0.779 0.91 0.092426417 0.277279251 > 3 3.625 2.972 2.766 3.335 12.698 1.289704002 3.869112006 > 4 0.088 0.1 0.12 0.136 0.444 0.045095966 0.135287898 > 5 9.392 5.798 9.835 8.01 33.035 3.355282068 10.0658462 > 6 0.153 0.075 0.01 0.517 0.755 0.076683456 0.230050367 > 7 7.4 7.565 7.703 6.415 29.083 2.953887343 8.86166203 > 8 0.221 0.606 1.321 0.539 2.687 0.272911849 0.818735546 > 9 0 0 0 0 0 0 0 > 10 1.381 0.368 1.196 1.091 4.036 0.409926394 1.229779182 > 11 0.066 0.025 0.039 0.017 0.147 0.014930421 0.044791264 > 12 0.166 0.041 0.062 0.024 0.293 0.029759275 0.089277825 > 13 0 0 0 0 0 0 0 > 14 0.71 0 0.005 0.074 0.789 0.08013675 0.240410251 > 15 0.239 0.17 0.208 0.286 0.903 0.091715444 0.275146333 > 16 0 0 0 0 0 0 0 > > 14:03 System wide checks ok - WR same difference as before > Statistics - attachment 7 > Temperatures - attachment 8 > Bias and leakage currents - attachment 9
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown