> > 11:30 BNC PB-5 pulser polarity chnaged from positive to negative (using LOCAL control) > Swap BNC cables (top + bottom & left + right) from BNC PB-5 and Cooknell SA1 Sum Amp outputs > Switch Cooknell SA1 Sum Amp output from negative to positive > > Observe pulser peak of c. 15 ch FWHM for aida08 and c. 35 ch FWHM for aida14 > > This probably indicates > - noisy Cooknell SA1 > - problem with T and/or Lemo-00 cable between BNC PB-5 and Cooknell SA1 > > > Investigate noise situation of AIDA (no DSSSDs connected) > > > > Figs 1-6: Waves, Pulser Peaks + Widths *before* any changes > > - aida16 very noisy ASICS 1&2, normal ASICS 3&4 > > - back-side aidas (02,04,06,08) worse resolution than front-side > > - high-frequency noise still noticeable in waveforms > > > > Figs 7-8: Remove pulser in (from NIM rack) only > > - no noticable change > > > > Figs 9-10: Remove all pulser cables from adapter boards > > - looks improved > > > > Figs 11-12: HV Braid->GND Jumpers removed > > > > Fig 13-14: All HV cables removed > > - aida06, aida14 isn't updating > > - very noticable improvement > > > > Fig 15-16: Intermediate HV cables re-added > > - signal worse in FEE64s with HV cables > > - aida09, aida01, aida10, aida13, aida05, aida14 don't have HV interconnect cables, look good > > > > Conclusion: We see noticeable improvements removing the interconnect cables between FEE64s. > > > > Pulser widths now: > > - aida14 (-ve amplitude) = 13.5 channels > > - aida08 (+ve amplitude) = 40 channels (?) Removed the T-piece between pulser and summing amplifier pulser FWHM still ~30 channels - not the T-piece, probably summing amp Checked the noise of HV and LV on battery DSO - LV - no noticeable noise on any channel (< 5 mV rms) - HV - noticable periodic signal (~100 kHz, 100 mV Vpp) on both core and braid channels, common to both independent of bias voltage See figs 1-6 : 0V, 10V, 20V, 50V, 100V, 0V (high photo resolution) of bias voltage AC coupled 1MOhm Ch1 = HV Core, Ch2= HV Braid, Math=Ch1-Ch2 Filtering on AIDA front end ~ 10 nF (gnd), 3 kOhm (series) - low pass ~ 33kHz rolloff 100 kHz would be attenuated factor of 5 maybe - 20 mV signal - still quite high for ASICs Try introducing additional inline filtering of maybe 3 kHz (1 nF gnd, 3 kOhm series) Check on one DSSSD, if see improvement can migrate to adapter boards in new revision Things to do: TD: Inline filters NH: Check same behaviour other N1419ET HV supplies Check line voltages from CAEN NIM bin
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown