Retrying AIDA DataAcq v10 |
|
|
Startup AIDA with ribbon cable connected to aida03 and aida07 for noise
Setup and run with waveforms enabled. Discriminators ADC power etc as default
Try to push above 200k as this is where we saw issues before... lowering threshold to 0x3 pushes rates to
aida03 - 320k
aida07 - 254k
Startup merger and observe rates
aida03 - 224k
aida07 - 213k
Rate drop observed as before.
Now update aidacommon to point to AidaExecV10 and powercycle FEEs
Rates again with 0x3
aida03 - 315k
aida07 - 252k
Restart with data transfer ON
aida03 - 317k
aida07 - 262k
No errors in merger terminal or "Merge time errors" statistic
Will keep running |
|
|
|
|
|
|