AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
DESPEC
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Sat Mar 29 11:37:52 2025
Author
*
:
Subject
*
:
01.35 DSSSD bias & leakage current OK - Grafana - attachment 1 FEE64 temperatures OK - attachment 2 ADC data item stats OK - attachment 3 Merger OK - attachment 4 04.05 DSSSD bias & leakage current OK - Grafana - attachment 5 FEE64 temperatures OK - attachment 6 ADC data item stats OK - attachment 7 Merger OK - attachment 8 08.20 DSSSD bias & leakage current OK - Grafana - attachment 9 FEE64 temperatures OK - attachment 10 ADC data item stats - attachment 11 increased rates observed esp. DSSSD#2 n+n Merger etc - attachment 12 rate increased x2 cf. overnight WR timestamp - attachment 13 aida03 out sequence 09.25 MBS data relay restarted Merger data links - attachment 14 aida03 rate zero per FEE64 1.8.W spectra - 20us FSR - attachments 15-16 per FEE64 Rate spectra - attachment 17 increased rate for DSSSD#2 n+n FEE64s in particular MIDASsort online analysis - attachments 18-19 per DSSSD e_front versus e_back for LEC (20keV/channel) and HEC (20MeV/channel) observe light ions (LEC) c. 2MeV observe low rate of high energy ions (HEC) c. 600MeV similar energies in both DSSSDs for LEC and HEC implying both types of event have range >> 2mm Si 10.09 DAQ STOP aida03 does not respond - reboot aida03 DAQ RESET/SETUP etc Synchronise ASIC clocks All system wide checks OK *except* FPGA errors Data transfer disabled Histograms & stats zero'd DAQ GO Merger restarted Data transfer enabled DAQ GO WR timestamp OK - attachments 20-21 ADC data item stats OK - attachment 22 rates status quo ante Merger etc OK - attachment 23 14.58 DSSSD bias & leakage current OK - Grafana - attachment 24 FEE64 temperatures OK - attachment 25 ADC data item stats OK - attachment 26 Merger etc OK - attachment 27 18.13 DSSSD bias & leakage current OK - Grafana - attachment 28 FEE64 temperatures OK - attachment 29 ADC data item stats OK - attachment 30 Merger etc OK - attachment 31 20.30 Primary c, few kHz 170Er beam to S4 - upstream s/steel flange removed Start of stopping range calibration in the implantation stack - currently ion appear to be stopping in DSSSD#1 (upstream) Decay and implant events as function of time showing spill structure - attachment 32 per DSSSD e_front versus e_back (HEC, 20MeV/channel) - attachment 33 per DSSSD x versus y hit pattern (HEC) - attachment 34 mapping to be configured but clear ions are mostly implanted in centre of DSSSD#1 2D colour/contour levels - attachment 35 per DSSSD m_front versus m_back (HEC) - attachment 36 per DSSSD per pixel HEC-HEC time (4.096us/channel) - attachment 37 23.44 aida02 has stopped running DAQ STOP aida02 rebooted Data transfer disabled DAQ RESET/SETUP Synchronise ASIC clocks All system wide checks OK *except* FPGA errors Histograms & stats zero'd DAQ GO Merger restarted Data transfer enabled DAQ GO
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown