Subject
*
:
> 01.35 DSSSD bias & leakage current OK - Grafana - attachment 1 > > FEE64 temperatures OK - attachment 2 > > ADC data item stats OK - attachment 3 > > Merger OK - attachment 4 > > 04.05 DSSSD bias & leakage current OK - Grafana - attachment 5 > > FEE64 temperatures OK - attachment 6 > > ADC data item stats OK - attachment 7 > > Merger OK - attachment 8 > > 08.20 DSSSD bias & leakage current OK - Grafana - attachment 9 > > FEE64 temperatures OK - attachment 10 > > ADC data item stats - attachment 11 > increased rates observed esp. DSSSD#2 n+n > > Merger etc - attachment 12 > rate increased x2 cf. overnight > > WR timestamp - attachment 13 > aida03 out sequence > > 09.25 MBS data relay restarted > > Merger data links - attachment 14 > aida03 rate zero > > per FEE64 1.8.W spectra - 20us FSR - attachments 15-16 > > per FEE64 Rate spectra - attachment 17 > increased rate for DSSSD#2 n+n FEE64s in particular > > MIDASsort online analysis - attachments 18-19 > per DSSSD e_front versus e_back for LEC (20keV/channel) and HEC (20MeV/channel) > observe light ions (LEC) c. 2MeV > observe low rate of high energy ions (HEC) c. 600MeV > similar energies in both DSSSDs for LEC and HEC implying both types of event have range >> 2mm Si > > > 10.09 DAQ STOP > aida03 does not respond - reboot aida03 > > DAQ RESET/SETUP etc > > Synchronise ASIC clocks > All system wide checks OK *except* FPGA errors > > Data transfer disabled > Histograms & stats zero'd > DAQ GO > > Merger restarted > > Data transfer enabled > DAQ GO > > WR timestamp OK - attachments 20-21 > > ADC data item stats OK - attachment 22 > rates status quo ante > > Merger etc OK - attachment 23 > > > 14.58 DSSSD bias & leakage current OK - Grafana - attachment 24 > > FEE64 temperatures OK - attachment 25 > > ADC data item stats OK - attachment 26 > > Merger etc OK - attachment 27 > > 18.13 DSSSD bias & leakage current OK - Grafana - attachment 28 > > FEE64 temperatures OK - attachment 29 > > ADC data item stats OK - attachment 30 > > Merger etc OK - attachment 31 > > > 20.30 Primary c, few kHz 170Er beam to S4 - upstream s/steel flange removed > Start of stopping range calibration in the implantation stack - currently ion appear to be stopping in DSSSD#1 (upstream) > > > Decay and implant events as function of time showing spill structure - attachment 32 > > per DSSSD e_front versus e_back (HEC, 20MeV/channel) - attachment 33 > > per DSSSD x versus y hit pattern (HEC) - attachment 34 > mapping to be configured but clear ions are mostly implanted in centre of DSSSD#1 > > 2D colour/contour levels - attachment 35 > > per DSSSD m_front versus m_back (HEC) - attachment 36 > > per DSSSD per pixel HEC-HEC time (4.096us/channel) - attachment 37 > > 23.44 aida02 has stopped running > DAQ STOP > aida02 rebooted > > Data transfer disabled > > DAQ RESET/SETUP > > Synchronise ASIC clocks > All system wide checks OK *except* FPGA errors > > Histograms & stats zero'd > DAQ GO > > Merger restarted > > Data transfer enabled > DAQ GO > > > > > > > > > > >
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.4-unknown