AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DESPEC  ELOG logo
Message ID: 617     Entry time: Sun Apr 28 15:49:58 2024
Author: TD 
Subject: DAQ restart short(er) cut 
16.45 aida04 stopped producing data

      DAQ STOP (workspace 2, display 1, browser 'Run Control' tab)

       aida04 did not stop, all other FEE64s stopped

      restart Merger (workspace 3, display 2, select 'NewMerger' icon)

      SETUP Merger (workspace 3, display 1, browser 'NewMerger' tab)
      GO Merger (workspace 3, display 1, browser 'NewMerger' tab)

       aida04 now stops

      disable *all* #1 data transfer 

      DAQ GO (workspace 2, display 1, browser 'Run Control' tab)
      check WR timestamps OK (workspace 2, display 1, GSI WR Timestamp Control)

      DAQ STOP (workspace 2, display 1, browser 'Run Control' tab)
      enable *all* #1 data transfer
      DAQ GO (workspace 2, display 1, browser 'Run Control' tab)


      No reboot or power cycle required. Just clear the Merger data links, restart DAQ.
      