<p>Hi, see the attached files in the original comment. I think the BACKUPCorrupt is quite old now.</p>
<p>The Options data gets corrupted and for example the ASIC folder gets set to 'undefined' which I think is why the ASIC data loads incorrectly.</p>
<p> </p>
<table align="center" border="1" cellspacing="1" style="width:98%">
<tbody>
<tr>
<td style="background-color:#486090">Quote:</td>
</tr>
<tr>
<td style="background-color:#ffffb0">
<p>This looks like the Options not the ASIC data. That will be in the CONTENTS file of the FEE64 named directory within the dated EXPERIMENT directory. Looks like the latest is at /MIDAS/DB/EXPERIMENTS/AIDA/2019Oct31-13.24.23/aida10 ?</p>
<p>A quick look at this file and it looks normal , not all 0xad ? </p>
<p>Looked at the Options file in the /MIDAS/DB/EXPERIMENTS/AIDA/Options.BACKUPCorrupt/aida10 and the worst bit is the name of the Data Acquistion program. That could welll cause you problems with readout as it won't understand some of the new data.</p>
<p> </p>
<table align="center" border="1" cellspacing="1" style="width:98%">
<tbody>
<tr>
<td style="background-color:#486090">Quote:</td>
</tr>
<tr>
<td style="background-color:#ffffb0">
<p>Often aida10 database seems to get corrupted (ASIC values are all 0xad)<br />
Unsure why it's only aida10, might be related to weird alpha rate behaviour at the moment.</p>
<p> </p>
<p>Attached is corrupted database and correct database</p>
</td>
</tr>
</tbody>
</table>
<p> </p>
</td>
</tr>
</tbody>
</table>
<p> </p> |