Entry time:
Thu Apr 3 19:29:07 2025
Author
*
:
Subject
*
:
Fit: line + power law + line Free parameters: 2x boundary points between lines Algorithm: Nelder-Mead, 10 iterations. (centroid correct) Attach 1 - height (difference between intercepts) Attach 2-8 - Signals with H~110, different t values (see filenames). Note t=370 and t=870 show discontinuities in the middle of the rising front. Pick-up? Attach 9 - Comparison of the above. Note t=370-570 look visually similar in spite of very different fit results. Pulser *not* shown Attach 10 - Heat map Attach 11 - rise times (x-diff between boundary points), for H>20 (no noise)