AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
ISOLDE
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Thu Aug 21 11:08:23 2025
Author
*
:
Subject
*
:
<p>Alpha Calibration Runs (need to check settings in logbook)</p> <p>0-63: dE detector and 32-47 is n+n; 64-127 E detector and 96-111 is n+n; 128-191 HI detector</p> <p>Run 13: alpha source in fromt of dE detector (0-63). All detectors connected.</p> <ul> <li>0-15 OK</li> <li>16-31 OK</li> <li>32-47 pulser appears at higher amplitude, alphas in a similar spot</li> <li>48-63 OK</li> <li>64-79 ch64 low gain but only for pulser (alphas look fine)</li> <li>80-95 ch83 low gain, ch88 bad resolution. some strips show alphas</li> <li>96-111 ch102 no alphas, ch103 low gain</li> <li>112-127 pulser OK</li> <li>128-191 (HI detector) looks ok</li> <li> </li> <li> </li> </ul> <p>dE Layer is Removed</p> <p>Run 15: alpha source in front of E detector, no dE</p> <ul> <li>0-15 OFF</li> <li>16-31 OFF</li> <li>32-47 OFF</li> <li>48-63 OFF</li> <li>64-79 ch64 low gain but only for pulser (alphas look fine)</li> <li>80-95 ch83 low gain, ch88 bad resolution.</li> <li>96-111 ch102 no alphas, ch103 low gain</li> <li>112-127 OK</li> </ul> <p>Run 16: alpha source in front of E detector, no dE</p> <ul> <li>0-15 OFF</li> <li>16-31 OFF</li> <li>32-47 OFF</li> <li>48-63 OFF</li> <li>64-79 ch64 low resolution, low gain but only for pulser</li> <li>80-95 ch83 low gain, ch88 bad resolution.</li> <li>96-111 ch102 /ch103 problem</li> <li>112-127 OK</li> </ul> <p>Run 18 does not seem to be in Run book</p> <p>Run 18: alpha source in front of E detector,</p> <ul> <li>0-15 OFF</li> <li>16-31 OFF</li> <li>32-47 OFF</li> <li>48-63 OFF</li> <li>64-79 ch64 as Run 16</li> <li>80-95 ch83 as Run 16</li> <li>96-111 alphas there but there are two pulser peaks in all segments, and a lot of alpha peaks...</li> <li>112-127 OK</li> </ul> <p>Run 19: same settings as Run 16</p> <ul> <li>0-15 OFF</li> <li>16-31 OFF</li> <li>32-47 OFF</li> <li>48-63 OFF</li> <li>64-79 ch64 as Run 16</li> <li>80-95 ch83 as Run 16</li> <li>96-111 102/103 empty/low gain</li> <li>128-143 OK</li> <li>144-159 152-154 low resolution</li> <li>160-175 OK</li> <li>176-191 OK</li> </ul> <p>For later runs the information is taken from logbook as no runs have been saved:</p> <p>Run 23: E detector switched to #2951-22</p> <ul> <li>0-15 OFF</li> <li>16-31 OFF</li> <li>32-47 OFF</li> <li>48-63 OFF</li> <li>64-79 ch64 as Run16</li> <li>80-95 ch83 as Run 16</li> <li>96-111 102/103 empty/low gain</li> <li>112-127 OK</li> </ul> <p>Run 24 Cable for 1 mm E detector must be faulty; Check new cable</p> <ul> <li>64-79 OK</li> <li>80-95 ch 83 low gain</li> <li>96-111 ch 101, ch 103 low gain </li> <li>112-127 OK</li> </ul>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
Drop attachments here...
Draft saved at 00:00:00
ELOG V3.1.3-7933898