> Faraday cup readout at the end of our chamber should change based on whether or not the target is in and also the 59Cu beam energy. > > The effect could be as much as 10 to 20%. At some point, we should check the Faraday cup reading with the CH2 target and with the empty target. For comparison, csd predicts 5.00MeV/u 59Cu?+ -> 4.66MeV/u 59Cu24+ following the 0.5mg/cm2 (CH2)n target w29> csd Charge State Distributions in Solid and Gaseous Targets Is target solid(1) or gaseous(2) ? 1 Enter energy (MeV), mass (amu) and charge of ion: 275 59 29 Enter minimum and maximum charge states: 1 29 Energy: 275.0 QNOT: 24.1 RHO: 1.3 EPS: -64.6 Charge % 1 0.0 2 0.0 3 0.0 4 0.0 5 0.0 6 0.0 7 0.0 8 0.0 9 0.0 10 0.0 11 0.0 12 0.0 13 0.0 14 0.0 15 0.0 16 0.0 17 0.0 18 0.0 19 0.1 20 0.5 21 2.7 22 9.6 23 21.9 24 30.3 25 23.6 26 9.4 27 1.7 28 0.1 29 0.0 Options available: end(1) , medium(2) , ion(3) , charge states(4)