AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
ISOLDE
Draft saved at 00:00:00
Fields marked with
*
are required
Entry time:
Thu Nov 9 08:20:21 2017
Author
*
:
Subject
*
:
<p>0) If target or line drop, STOP THE BEAM!!</p> <p>1) If you SEE target or line current go down (top right window of monitors next to the corridor): </p> <p>Use Knobs open application (monitor below); remember set value; type 0 in set window; click Mode - Reset; click Mode - On. increase current in steps of 100 A</p> <p>2) If Target or line current off and it happened a while ago</p> <p>Use Knobs open application (monitor below); type 0 in set window; click Mode - Reset; click Mode - On Use Isolde Target heating GPs application (in monitor below);</p>