Entry time:
Tue Mar 25 20:24:00 2025
Author
*
:
Subject
*
:
<p>Strip 13 ampltiude spectra for the LiF and B samples. Also a picture of a simulation of what would be expected in a 20 um detector in terms of energy deposition for several reactions (assuming a thin sample).</p> <p>- for B-10 n,alpha, the dominant reaction is n,alpha_1, so just seeing one peak makes sense</p> <p>- for LiF we would expect 2 peaks, one around 1 MeV and one around 1.8. In the data it looks more like 1 peak while the lower energy "peak" is likely noise. My guess is that the sample is quie thick, which leads to a lower energy alphas, and a lower energy triton. As a consequence, the two peaks merge.</p> <p>Conclusion:</p> <p>- check the other LiF samples to see if we have any thinner samples</p> <p>- try and rotate LI sample to confirm that the direction we are using now is the correct one.</p>