ID |
Date |
Author |
Subject |
|
6
|
Fri Sep 13 08:43:13 2024 |
CLW | Cabling |
Detector |
Bunker Signal |
patch panel |
signal cable |
ADC Card |
name in daq |
dE 0 |
71 |
220804 |
10 |
5348 |
DEED 1 |
dE 1 |
72 |
220805 |
11 |
5348 |
DEED 2 |
dE 2 |
73 |
220806 |
12 |
5348 |
DEED 3 |
dE 3 |
74 |
220807 |
13 |
5348 |
DEED 4 |
dE 4 |
75 |
220808 |
14 |
4679 |
DEED 5 |
dE 5 |
76 |
220809 |
15 |
4679 |
DEED 6 |
dE 6 |
77 |
220810 |
16 |
4679 |
DEED 7 |
dE 7 |
78 |
220811 |
17 |
4679 |
DEED 8 |
dE 8 |
79 |
220812 |
18 |
4676 |
DEED 9 |
dE 9 |
80 |
220813 |
19 |
4676 |
DEED 10 |
dE 10 |
81 |
220814 |
20 |
4676 |
DEED11 |
dE 11 |
82 |
220815 |
21 |
4676 |
DEED 12 |
dE 12 |
83 |
220817 |
23 |
4677 |
DEED 12 |
dE 13 |
84 |
220818 |
24 |
4677 |
DEED 13 |
dE 14 |
85 |
220819 |
25 |
4677 |
DEED 14 |
dE 15 |
86 |
220820 |
26 |
4677 |
DEED 15 |
|
|
|
|
|
|
Efront 0 |
95 |
220821 |
27 |
4674 |
EDET 1 |
Efront 1 |
96 |
220822 |
28 |
4674 |
EDET 2 |
Efront 2 |
97 |
220823 |
29 |
4674 |
EDET 3 |
Efront 3 |
100 |
220824 |
30 |
4674 |
EDET 4 |
Efront 4 |
101 |
220825 |
31 |
4684 |
EDET 5 |
Efront 5 |
102 |
220826 |
32 |
4684 |
EDET 6 |
Efront 6 |
103 |
220827 |
33 |
4684 |
EDET 7 |
Efront 7 |
104 |
220828 |
34 |
4684 |
EDET 8 |
Efront 8 |
105 |
220829 |
35 |
4683 |
EDET 9 |
Efront 9 |
106 |
220830 |
36 |
4683 |
EDET10 |
Efront10 |
107 |
220831 |
37 |
4683 |
EDET11 |
Efront11 |
108 |
220832 |
38 |
4683 |
EDET12 |
Efront12 |
109 |
220833 |
39 |
4682 |
EDET13 |
Efront13 |
110 |
220834 |
40 |
4682 |
EDET14 |
Efront14 |
111 |
220835 |
41 |
4682 |
EDET15 |
Efront15 |
112 |
220836 |
42 |
4682 |
EDET16 |
|
|
|
|
|
|
Eback 0 |
113 |
220837 |
43 |
5344 |
EDET17 |
Eback 1 |
114 |
220838 |
44 |
5344 |
EDET18 |
Eback 2 |
116 |
220839 |
45 |
5344 |
EDET19 |
Eback 3 |
117 |
220840 |
46 |
5344 |
EDET20 |
Eback 4 |
118 |
220841 |
47 |
4680 |
EDET21 |
Eback 5 |
119 |
220842 |
48 |
4680 |
EDET22 |
Eback 6 |
120 |
220843 |
49 |
4680 |
EDET23 |
Eback 7 |
121 |
220844 |
50 |
4680 |
EDET24 |
Eback 8 |
122 |
220845 |
51 |
5345 |
EDET25 |
Eback 9 |
123 |
220846 |
52 |
5345 |
EDET26 |
Eback10 |
124 |
220847 |
53 |
5345 |
EDET27 |
Eback11 |
125 |
220848 |
54 |
5345 |
EDET28 |
Eback12 |
126 |
220849 |
55 |
4073 |
EDET29 |
Eback13 |
127 |
220850 |
56 |
4073 |
EDET30 |
Eback14 |
128 |
220851 |
57 |
4073 |
EDET31 |
Eback15 |
129 |
220852 |
58 |
2872 |
EDET32 |
|
|
5
|
Fri Sep 13 08:12:04 2024 |
CLW | How to Edinburgh Chamber |
A how to from last year, still relevant for this measurement (only the vacuum valve may have moved depending on the pump. |
Attachment 1: HOW_TO.docx
|
|
4
|
Tue Aug 27 09:01:01 2024 |
CLW | Prep Meeting Slides |
|
Attachment 1: K40_prepmeeting.pptx
|
|
3
|
Wed Jul 31 11:15:09 2024 |
CLW, Francisco | reference samples, 10B, LiF, blank |
B10 and LiF samples have arrived at CERN.
There are 4 LiF sample, 4 Boron sample and one blank sample. All samples are attached to a square and are in good condition. |
Attachment 1: Experiment_40K_Reference_Samples_1.jpeg
|
|
Attachment 2: Experiment_40K_Reference_Samples_2.jpeg
|
|
Attachment 3: B_Sample_2_1.jpeg
|
|
Attachment 4: LiF_Sample_1_1.jpeg
|
|
|
2
|
Thu Jun 20 12:41:22 2024 |
CLW | To Prepare |
- new Kapton windows for chamber (underway, waiting for workshop)
- LiF and B samples from Daresbury: under production, will be shipped directly to CERN
- shorter flat cable: will try again to make a proper flat cable that is shorter. check with Tom |
|
1
|
Tue Apr 16 08:57:12 2024 |
CLW | New Elog tab for 40K experiment |
This is a new elog tab dedicated to the 40K(n,p) and (n,alpha) experiment. Things to be prepared before the run (start of run TBD):
- new almunised Kapton windows for chamber (Peter has ordered material)
- Lemo - BNC converters (most availanble, 10 new ones in my office)
- 10B and LiF reference samples: being prepared by P. Morrall in Daresbury
- 40K samples: one 40K (16% enriched) prepared by PSI, one highly enriched 40K sample will be produced by implantation at iThemba labs. Implantation will commence around May for about 6 weeks. |