25
|
Tue Mar 3 15:28:37 2026 |
FGI, SB, CLW | Run 59 | Before this run, we change the target for
the neutron source. We are using a Triton
target of ~200 ug/cm². |
| |
24
|
Tue Mar 3 08:25:45 2026 |
FG,SB,CLW | Run 58 |
start: 08:24:49, 3.3.2026
stop: 10:13:25
blocks:
3062
Flux monitor
Start: 09:20:43 |
| |
23
|
Tue Mar 3 08:24:06 2026 |
FG,SB,CLW | Run 57 | Start: 15:45:30, 2.3. 2026
Stop: 07:57:05 3.3. 2026
Blocks: 25524 |
| |
22
|
Mon Mar 2 13:50:20 2026 |
FGI, TD, SB, CLW | Cabling | The cables are plug in this way.
Cable 0 connected to Preamp A,
Positive output. (n+n side, toward the sample) |
| |
21
|
Mon Mar 2 13:24:11 2026 |
FG,SB,CLW | Run 56 |
start: 13:28:38, 2.3.2026
stop: 15:05:22,
2.3.2026
blocks: 2206
LiF
no. 7 in beam |
| |
20
|
Mon Mar 2 13:22:52 2026 |
FG,SB,CLW | Run 55 |
start: 10:14:0531 2.3.26
stop: 12:57:08
2.3.26
blocks: 3855
NaCl No. 4 |
| |
19
|
Mon Mar 2 11:11:18 2026 |
FGI, TD, SB, CLW | Second configuration. | After the first weekend, we change the
setup configuration. We removed the shadow
cone, and we placed the chamber closer to |
 | |
18
|
Mon Mar 2 10:39:30 2026 |
SW, TD, SB, CLW | Detector SetUp. First Configuration | The first sample on beam is the NaCl target
#4. The shado cone was placed between the
LiF target and the chamber. |
9x | |
17
|
Mon Mar 2 10:38:42 2026 |
CLW | detector voltage change before Run 55 | preamp B detector (DSSSD 2) on 100 V, DSSSD
1 still on 70 |
| |
16
|
Mon Mar 2 09:47:13 2026 |
CLW | Clock Synchronisation Edinburgh PC , Geel monitor PC | T=0: Edinburgh Time 9:39:00
T=1:40: Geel Time 10:37:00
|
| |
15
|
Mon Mar 2 09:43:05 2026 |
FG,SB,CLW,TD | Run 54 |
start: 09:36:05 2.3.26
stop: 09:43:49
2.3.26
blocks: 14
Cu rod taken
out, run in neutron beam with NaCl target. |
| |
14
|
Sat Feb 28 12:09:56 2026 |
TD | Offline analysis data file R52 |
Offline data analysis of data file R52
c. 1h 2.25MeV neutrons from 10uA p+ + 410ug/cm2 |
8x | |
13
|
Sat Feb 28 09:20:14 2026 |
TD | MIDAS DAQ configuration |
MIDAS DAQ configuration files
|
8x | |
12
|
Sat Feb 28 08:59:14 2026 |
SB, TD, FGI | R53 |
start: 16:14:44 27.2.26
stop: 08:38:26 2.3.26
|
6x | |
11
|
Fri Feb 27 15:17:59 2026 |
SB, TD, FGI | R52 | Start: 15:06:06 GMT
Stop: 16:13:45
Blocks: 875
|
| |
10
|
Fri Feb 27 14:38:28 2026 |
SB, TD, FGI | R51 |
start: 14:31:03 (w23 is set to GMT)
stop: 14:38:09
|
| |
8
|
Fri Feb 27 12:41:34 2026 |
SB, TD, FGI | Friday 27 February 2026 |
BNC PB-5 settings
Amplitude 5.0V
|
11x | |
7
|
Thu Feb 12 12:18:16 2026 |
CLW | paper | |
| |
6
|
Tue Feb 10 09:31:47 2026 |
Francisco Garcia Infantes | Detector Voltage vs Current | Analysis
of how the current changes with increasing
voltage for both detectors. |
| |
5
|
Tue Feb 10 09:03:26 2026 |
Francisco Garcia Infantes | Contents of shipment boxes | BOX
A
|
|
|