AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nToF  ELOG logo
Message ID: 7     Entry time: Fri Oct 16 15:41:14 2015
Author: Sarah Lonsdale 
Subject: 06/10/15 Changes to DAQ and pulser settings 

 Pulser out of 5,6,7 EFED- extended to 32ms

Changed full scale on ADC to 0.2V,
Offset changed by factor of 10.
Zero suppression on, de -3mV thresh
E +-5mV thresh
Post sample 4096

5pm increased post sample for spd-02886 to 8192 as higher sample rate due to pick up.

Corrected EBED 4 offset.

(Again, all DAQ settings also recorded to the nToF erunbook)

Changed pulser to 13ms.

Attachment 1: 2015-10-06_delay.jpg  85 kB  | Hide | Hide all
2015-10-06_delay.jpg
Attachment 2: 2015-10-06_trig.jpg  81 kB  | Hide | Hide all
2015-10-06_trig.jpg
ELOG V3.1.4-unknown