  27   Fri Sep 9 10:01:18 2016 SarahLeakage currents 09.09.16

EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA

  21   Tue Aug 9 15:57:52 2016 SarahLeakage currents 09.08.16

 Morning - 9am

E= 0.03uA
dE= 0.04uA
PHDI= 0.06uA

 

Afternoon - 4.30pm

E=0.03uA
dE= 0.03uA
PHDI=0.05uA
 

  20   Mon Aug 8 11:02:13 2016 SarahLeakage currents 08.08.16

 E 0.03 uA
dE 0.04 uA
PHDI 0.05 uA

 

Boron target 1 towards PHDI and Boron target 3 towards dE-E.

Mylar target gluing in electronics lab.

  25   Fri Sep 2 12:01:57 2016 SarahLeakage currents 02.09.16

E 0.03
dE 0.05
PHDI 0.12


Check on PHDI pulser width:
205170 (first in beam run) - 1.1% FWHM (at 8275 ch)
205439 (01/09/16) - 1.0% FWHM (at 8008 ch)

Seems to be holding up OK at present.

  19   Wed Aug 3 14:48:09 2016 SarahLeakage currents 02.08 - 03.08

 02.08:

dE = 0.03 uA

E = 0.03 uA

PHDI = 0.04 uA

 

03.08:

dE = 0.03 uA

E 0.04 uA

PHDI = 0.04 uA

  29   Thu Oct 6 09:28:33 2022 ClaudiaItems to be replaced for next run

Missing/broken items identified

- long rails for fixing chamber on support

- vacuum valve (ours is broken)

- at least 2 lemo - BNC converters

- short M3 screws (photo)

  28   Thu May 26 09:20:32 2022 Nick / ClaudiaInventory of Items at n_TOF for (n,cp) experiments

Detectors currently in the boxes:

2x MSL type W1(SS)-50, 2902-4 (53um), 2940-6 (55um)

1x MSL type W1(SS)-20 2837-33 (20um)

1x MSL type W1(DS?) 1230-10  (500 or 300 um)

1x MSL type W1(DS)-500 1194-9 (494um)

 

Three aluminium crates contain 26Al(n, alpha) kit from EAR2, and was in the barracks (building 6547) near detector lab by EAR1 entrance. A list is attached and photos can be found on Dropbox:

https://www.dropbox.com/sh/68k1xove2zr1bmj/AADKvN8wR_Ia2EwZMOXZqdMCa?dl=0

  49   Thu Aug 10 10:05:48 2023 CLWGafchromics Foil

Gafchromics foil was mounted on empty brass frame back to back with Li sample

Neutron beam goes well through the sample. Centered ~1 cm from sample center. Conclusion: no changes needed (too risky to make it worse and it is ok now)

  11   Wed Jul 27 13:20:53 2016 SarahGafchromic images
  84   Mon Jun 23 09:36:32 2025 CLWExpected Spectra for Li and B in a 50 um Si detector

B looks as we are used to , Li tritons are now stopped in the detector and should appear around 2.8 MeV. 

  71   Mon Oct 2 08:53:06 2023 EmmanuelEmpty Frame

An empty frame (on the top) was placed on Friday night.

  18   Wed Aug 3 09:48:31 2016 SarahEFED10 alpha calibration checks

 

EFED10: (1 bin = 2 ch)

Pulser (DAQ):
- Centroid = 5396.8(6) ch
- FWHM = 41(1) ch = 0.7%
 

Pulser (Maestro):
- Centroid = 4042 ch
- FWHM = 82 ch = 1.9%
 

148Gd (DAQ):
- Centroid = 2215(1) ch
- FWHM = 57(9) ch = 2.6%

 

148Gd (Maestro):
- Centroid = 1722 ch
- FWHM = 30 ch = 1.7%

 
  60   Fri Aug 11 16:50:58 2023 Nikolay SosninEDET24

After inserting aluminium target, previously-dead channel 24 on EDET was re-plugged into a 12-bit card SPD02872. It is the only EDET on 12-bit card, the rest are on 14-bit. From pulsers, there appears to be a 90 ns offset from this EDET to others, with EDET24 preceeding the rest. The last channel on 14-bit cards was broken, hence havng to use 12-bit.

  78   Thu Sep 12 15:26:30 2024 NickEAR2 Periodic Noise
  59   Fri Aug 11 13:16:56 2023 Nikolay SosninE Front Incorrect Cabling

E front 2x16-way to 1x34-way IDC cable from the Junction Box to the IDC-Lemo 00 adaptor was found to be inserted upside-down - the 16-way IDC connectors did not have polarisation keys - meaning the E detector p+n junction strip signals collected with 26Al for the first night are not working. Signals from the dE p+n junction strips and E n+n Ohmic strips will be OK. The mistake occurred at the conclusion of the noise tests yesterday - see https://elog.ph.ed.ac.uk/nToF/52

The 2x16-way to 1x34-way IDC cable without polarisation keys has now been replaced.

Run 216417 and onwards have correct cabling. For runs before that, E back and dE are still reliable.

  68   Tue Sep 5 16:09:45 2023 EmmanuelDrop in gain for DEED 14

Dear all,

There was an issue with one of the strips of the deltaE detector (DEED 14), for run216644. The gain dropped to almost a factor of 3. Find attached.

Somehow, it was fixed, but still lags, when compared to other strips of deltaE. This was tested for a more recent run, run216651. Find attached.

I also checked a bit older run (run216637) and they look similar.. Find attached. Maybe we should figure out if this will be a problem for the DEED14 strips.

 

NOTE: The plots have the run number at the top-center.

 

Emmanuel Odusina

 

 

  38   Sun Oct 9 20:57:54 2022 Nikolay SosninDetectors in-beam, no target

After long beam-off, changed detector mount by moving it 2 cm forward into the beam, after removing LiF 3.

  88   Sat Jul 12 11:34:31 2025 SelinDetector-Cable Connections

List of the detectors and the connections.

  46   Thu Aug 10 09:20:37 2023 CLWDetector Signal Cabling Al26 Aug 2023
delta E detector Cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 72 2204803 9 02911 DEED-1
1 73 2204804 10 02911 DEED-2
2 74 2204805 11 02911 DEED-3
3 75 2204806 12 02911 DEED-4
4 76 2204807 13 02914 DEED-5
5 77 2204808 14 02914 DEED-6
6 80 2204809 15 02914 DEED-7
7 81 2204810 16 02914 DEED-8
8 82 2204811 17 02917 DEED-9
9 85 2204812 18 02917 DEED-10
10 86 2204813 19 02917 DEED-11
11 87 2204814 20 02917 DEED-12
12 88 2204815 21 02916 DEED-13
13 90 2204816 22 02916 DEED-14
14 95 2204817 23 02916 DEED-15
15 96 2204818 24 02916 DEED-16
E p side cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 97 2204819 25 4683 EDET-1
1 101 2204820 26 4683 EDET-2
2 103 2204821 27 4683 EDET-3
3 104 2204822 28 4683 EDET-4
4 105 2204823 29 4684 EDET-5
5 106 2204824 30 4684 EDET-6
6 107 2204825 31 4684 EDET-7
7 108 2204826 32 4684 EDET-8
8 109 2204827 33 4682 EDET-9
9 110 2204828 34 4677 EDET-10
10 111 2204829 35 4682 EDET-11
11 112 2204830 36 4682 EDET-12
12 113 2204831 37 4697 EDET-13
13 114 2204832 38 4697 EDET-14
14 116 2204833 39 4697 EDET-15
15 117 2204834 40 4697 EDET-16
E n side cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 118 2204835 41 5348? EDET-17
1 119 2204836 42 5348? EDET-18
2 120 2204837 43 5348? EDET-19
3 121 2204838 44 5348? EDET-20
4 123 2204839 45 4677 EDET-21
5 124 2204840 46 4677 EDET-22
6 125 2204841 47 4677 EDET-23
7 126 2204842 48 2872 EDET-24
8 127 2204843 49 4636 EDET-25
9 128 2204844 50 4636 EDET-26
10 129 2204845 51 4636 EDET-27
11 130 2204846 52 4636 EDET-28
12 131 2204847 53 4674 EDET-29
13 132 2204848 54 4674 EDET-30
14 133 2204849 55 4674 EDET-31
15 134 2204850 56 4674 EDET-32

 

  45   Thu Aug 10 09:10:02 2023 CLWDetector Setup Al26 Run 2023

dE Detector: W1-20 3186-9 20 um

E Detector: W1-150 3458-4 144 um

Voltages and Leakage Currents:

dE: 6 V, 0.02 muA

E: 50 V, 0.05 muA