24/02/15
1200: Update the FEE firmware on nnaida1-16 without problem.
Gone from file FEE_Oct12_27Nov13.bin ----> FEE_Riken_Apr14_24.bin
Included are a screen shot of the temperature window showing the new firmware versions and a stats screen.
12.15 Update MIDAS DAQ software
su
cp -r /MIDAS@aiidas /MIDAS@aidas.240214 ( /MIDAS is a link to /MIDAS@aidas )
exit
cd <update directory>
cp -r Data_Acq /MIDAS
cp -r Merger /MIDAS
cp -r TclHttpd /MIDAS
New versions of merge64.AD and master64 were installed in /MIDAS/Merger but the process crashed at startup
with multiple messages of the type:
MIDAS Data Link (12345) : Received SEGV signal; exiting.
(see attachment 3)
Is this related to the recent changes to the MIDAS TapeServer software to resolve problems with MIDAS Data
libraries libdataspy.so and libxfer.so ?
As a temporary workaround I have copied the backups of merge64.AD and master64 back to the install
directory /MIDAS/Merger. With the old verison of the merger we continue to obtain error messages
(see attachments 4-8)
|