Message ID: 564
Entry time: Sat May 13 02:35:53 2017
|
Author: |
TD, OH |
Subject: |
Saturday 13 May |
|
|
10.35 DAQ continues OK
Current file May2017/R6_246
ASIC settings 2017Mar27-16.12.39 *except*
slow comparator 0x20
LEC/MEC fast comparator 0xff
Detector biases & leakage currents OK - see attachments 1 & 2
FEE64 Temperatures OK - see attachment 3
'good events' statistics OK - see attachment 4
No warnings/errors reported by merger since DAQ GO - see attachment 5
*all* system wide checks OK
10.46 Rate/HitRate spectra - see attachments 6 & 7
1.8.L ADC spectra - see attachments 8 & 9
1.8.W waveforms - see attachments 10-13
10.51 Analysis of data file R6_245 - see attachment 14
Zero AIDA pause/resume
Zero idle-time
AIDA SYNC100 variations ~33/503400
12.03 E17/F11 ambient temperature +24.6 deg C, RH 39.4%, d.p. +9.9 deg C
Julabo FL11006 set point +20 deg C, actual +20.0 deg C, water level OK (c. 65%)
12.04 DAQ stops OK
Current file May2017/R6_250
Files May2017/R6* *deleted*
ASIC settings 2017Mar27-16.12.39 *except*
slow comparator 0x0a
LEC/MEC fast comparator 0xff
BNC PB-4 settings
Amplitude 90,000
x5 attenuator IN
t_r 50ns, tau_d 50us
polarity -
rate 250Hz range
delay MIN, tail pulse
Check ASIC Control x2
Zero all spectra
12.15 DAQ starts
File May2017/R7
14.30 Analysis of May2017/R7_29
ADC data synchronised - see attachments 15 & 16
14.37 Analysis of data file R7_29 - see attachment 17
AIDA pause/resume for some FEE64s
dead-time/idle-time <0.5%
AIDA SYNC100 variations ~300/100000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|