Entry  Mon Apr 20 06:53:24 2015, CG, TD, Progress 20th April + RPi procedure 7x
    Reply  Mon Apr 20 09:07:59 2015, CG, TD, Patrick Coleman-Smith, Progress 20th April + RPi procedure + reply 
       Reply  Mon Apr 20 09:38:15 2015, CG, TD, Patrick Coleman-Smith, Progress 20th April + RPi procedure + reply 
          Reply  Mon Apr 20 09:45:38 2015, CG, TD, Patrick Coleman-Smith, Progress 20th April + RPi procedure + reply ++  
Message ID: 57     Entry time: Mon Apr 20 06:53:24 2015     Reply to this: 59
Author: CG, TD 
Subject: Progress 20th April + RPi procedure 

20/04/15

1200: Complete all points on first part of check list, except checking the PSU voltages.

          System now in powered and has all network/HDMI cables attached.

1300: Connect RPi to power switch but when powered on it didn't find the switch. A reliable procedure to start seems to be...

  • connect USB power switch to RPI, make sure serial cable is disconnected from hub
  • power up RPi and power switch
  • check connection using dmesg, should see ...FT232RL for USB power switch on USB0
  • check connection from aidas1 by pinging RPi inet address 10.1.1.251
  • if good, Rly16 page should work from aidas1
  • connect serial cable, open PuTTY session, select AIDA console settings, open
  • should assign serial cable as USB1 an allow use of both the power switch and FEE console.

       Currently this all works, we can control the power switch both from the RPi and aidas1, and see the FEE console via PuTTY session.

1400: Powered on system and tried to set up DAQ but received error (attachment 1) when doing the initial system reset in Run Control.

          DAQ still usable for spectrum/temperature viewing, and all FEEs can be accessed to check ASIC control, but it seems timestamping will not be correct.

          Tried to perform manual ReSync from master timestamp window and received similar error (attachment 2).

1430: nnaida8 running quite hot (ASIC temp ~65oC) and ASIC temp on nnaida7+15 read as 0.00oC. Otherwise, from pulser/stats data, both seem to be working correctly.

          Unplugged power cable for nnaida7+8 at PSU end.

1600: Could timestamping issue originate from MACBs?

          In rebuilding AIDA MACB -> FEE cabling redone. Should it follow a particular pattern/tree?

          Current tree structure looks like (with MACB numbering going 1->11 L->R as you look at it):

                  MACB1(setting: 0) ------- out 1: MACB2 (setting: 2) ---------- out 1: MACB3 (setting: 2) -> nnaida3+4, 11+12

                                                                                                    ---------- out 2: MACB4 (setting: 3) -> nnaida19+20, 27+28

                                                                                                    ---------- out 3: MACB5 (setting: 3) -> nniada1+2, 9+10

                                                                                                    ---------- out 4: MACB6 (setting: 3) -> nnaida17+18, 25+26

                                              --------- out 2: MACB7 (setting: 3) ---------- out 1: MACB8 (setting: 3) -> nnaida21+22, 29+30

                                                                                                    ---------- out 2: MACB9 (setting: 3) -> nnaida7+8, 15+16

                                                                                                    ---------- out 3: MACB10 (setting: 3) -> nnaida5+6, 13+14   -----> nnaida5 is the master and this comes from output2.

                                                                                                    ---------- out 4: MACB11 (setting: 3) -> nnaida23+24, 31+32

          Patrick - Is this set up OK? Do certain FEEs need to receive the MACB signal from certain MACBs or just all at the same point in the tree?

                        Also, MACBs 2+3 are on setting 2 on the dial, whereas the others (except MACB1, the 'grandparent') are set to 3. It seems like a hard thing to change accidentally so are they supposed to be like this or should they all be on the same setting?

1630: Voltages to nnaida7+8 OK at PSU output (+6V, +6V, +6V, -6.5V, +8V). Issue with contact to cooling rack?

          With pulser input to all FEEs, only see pulser data in spectra for n-side (nnaida3+4, 7+8, 11+12, 15+16) FEEs. Other FEEs all show zero statistics.

 

 

Attachment 1: RunControl_error.png  267 kB  Uploaded Mon Apr 20 08:18:50 2015  | Hide | Hide all
RunControl_error.png
Attachment 2: MasterTSControl_error.png  229 kB  Uploaded Mon Apr 20 08:19:06 2015  | Hide | Hide all
MasterTSControl_error.png
Attachment 3: IMG_2841.JPG  6.455 MB  Uploaded Mon Apr 20 09:55:51 2015  | Hide | Hide all
IMG_2841.JPG
Attachment 4: IMG_2842.JPG  5.413 MB  Uploaded Mon Apr 20 09:57:55 2015  | Hide | Hide all
IMG_2842.JPG
Attachment 5: IMG_2843.JPG  5.220 MB  Uploaded Mon Apr 20 09:58:34 2015  | Hide | Hide all