> 10:18 Leakage and bias ok - Attachment 1
> FEE temperatures ok - Attachment 2
> Statistics - Attachment 3
> DAQ continues ok
>
> 10:23 DAQ stopped on R7_10
> Alpha run through night
>
> 10:28 MIDAS Sort spectra from the alpha run
> Ep versus En - Attachment 4
> x versus y 2D hit pattern - Attachment 5
> Front versus back multiplicity - Attachment 6
>
> 2D Hit pattern indicates detection of alphas in all 4 regions of each of the 6 detectors
> indicates cabling is ok
>
> 11:55 FEEs turned off after being unable to recover after crash
Please could you define this 'crash' to allow a better understanding of problems with the system.
For example.... what is unresponsive.... does a parse of the FEE64 log files ( before doing anything ) reveal a panic that is new? Does a STOP of the Tape work ? Does a Toggle of the MERGE pause state
work ?
Thus it will be possible to say that ..... FEE # is always the one responsible for DAQ failure or by < ???? > or the MERGE has found < ??? > problem.
Thanks in advance ;-)))
>
> 13:49 FEEs powered on again
> Pi monitor indicates panic on nnaida22 the FEE that crashed
>
> ReSync done on setup except for 23 and 24
> Master ReSync done succesfully
> ASIC settings loaded default to 2017Mar27
> Restoring 2017Oct22
>
> System wide checks ok
> Leakage and bias ok - Attachment 7
> FEE temperatures crashed - Attachment 8
>
> Upon reboot all rates across the FEEs appear lower
> In particular 13 and 14. Thresholds have been reduced back to 0xa for all ASICs on both FEEs
>
> Layout 1 linear common y of 2000 - Attachment 9
> Layout 1 log common y of 10 - Attachment 10
>
> All front side FEE64 1.8.W waveforms - 20us range - Attachment 11
> All back side FEE64 1.8.W waveforms - 20us range - Attachment 12
>
> All front side FEE64 1.8.W waveforms - 2ms range - Attachment 13
> All back side FEE64 1.8.W waveforms - 2m range - Attachment 14
>
> FEE64 nnaida13 1.*.W waveforms - Ibias LF 0xf - 2ms range - Attachment 15
>
> Statistics after switch and thresholds lowered - Attachment 16
> Pulser widths measured. On boards changed 10 out of 12 FEEs show greater than 10% improvements
> 11 out of 24 total show greater than 10%
> FEE stats post pulser width - Attachment 17
>
> New ASIC settings DB key: 2017Oct23-14.38.03
> Slow comparator 0xa for all FEE64s and all ASICs
> IBias LF feedback at 0xf for all front side FEEs except nnaida 2 which is at 0xc
> IBias LF feedback at 0xb for all back side FEEs
> ASIC settings DB file checked OK
>
> Ambient temperature +23.3 deg C, D.P +7.1 deg C, R.H. 35.2%
> Julabo FL11006 set point +20.0 deg C, water le
>
> 15:38 Merger and TapeServer screenshots - Attachments 17-18
> |