AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
AIDA |
 |
|
Message ID: 851
Entry time: Mon Jun 17 16:01:27 2019
|
Author: |
CB, CG, OH, TD |
Subject: |
Tuesday 18 June 00:00 - 16:00 |
|
|
00:00 New day. The DAQ continues OK
Beam setting 2 for enhanced yield of Sn100
No degrader
Statistics OK - see attach 1
FEE64 temps OK - see attach 2
Merger & Tape server OK - see attach 3 & 4
Bias OK - see attach 5
All system-wide checks OK, except nnaida7 fails ADC calibration
00:19 AIDA R2_473
DTAS 82
BigRIPS 2036
01:50 FEE temps and bias/leakage currents OK
Data rate continues at ~620k items/s and ~5.1MB/s
ASIC check performed successfully
02:29 DTAS run 85
BigRIPS run 2037
AIDA ~1.5GB into R2_492
02:30 DTAS reset correlation scaler at start of R2_493
Confirmed by change in value in Correlation status & control @ aidas1 window.
02:36 DTAS run 86 started
BigRIPS run 2038
AIDA file R2_494
04:38 DTAS run 88 stopped. AIDA run R2_512.
DTAS run 89 started.
BigRIPS run 2039
AIDA run R2_512 (1.8GB)
Temps + bias/leakage currents still ok
Data rate still ~600k items/s and ~5MB/s
Individual Good data rates remain roughly constant (see attachment 6)
All system-wide checks passed, except nnaida7 fails ADC calibration
05:48 Stats and histograms zeroed
06:28 DTAS run 91 stopped. AIDA run R2_528 at the time.
DTAS run 92 started
BigRIPS run 2040
AIDA run R2_528
07:50 Made some basic observations with the first file merged after the setting change
Attachment 7 shows implant x:y plots for each DSSD
Attachment 8 show PID for second setting with 100Sn highlighted in red and 96Ag in magenta
08:21 PID per DSSD Attachment 9
Sn100 per DSSD attachment 10
Sn100 Velocity against DSSD 11
Sn100 Velocity against DSSD Energy attachment 12
08:29 DTAS and BigRIPS stop
AIDA on file R2_546
DTAS starts file 95
BigRIPS run 2041
AIDA on file R2_547
08:53 Stats ok - attachment 13
Temps ok - attachment 14
System wide checks ok
ASIC check ok
Bias and leakage still ok though DSSD3 continues to rise - attachment 15
Merger continues with data rate around 700k - attachment 16
09:43 With the new implantation profile depositing most of the Sn100 in DSSD2 but some in the 3rd the
plan is to put in place a 200 micron degrader to bring the deposition into the centre of detector
2
10:15 Overnight MIDAS analysis has been completed.
Spectra have been exported to: /homes/npg/spectra/specs-2019Jun18-10.14.36
MIDAS will be switched to online mode with the change in degrader setting
10.33 DAQ stop
AIDA file RIBF147/R2_566
OH/AA/SN add 0.3mm Al degrader to Pb wall immediately upstream of the (CH2)n shield
10.35 Julabo FL11006 chiller set point +20 deg C actual +20.0 deg C
Water level c. 50% M-H markers
Temperature +24.1 deg C dew point +9.7 deg C RH 39.8%
10.39 DTAS starts file 98
BigRIPS run 2042
AIDA on file R2_567
11:06 Implantation events for the 2nd setting with 0,3mm Al plate - attachments 17-19
FEE64 Rate spectra - attachment 20
FEE64 HitRate spectra - attachment 21
1.8.L spectra - see attachments 22-25
nnaida1 73 ch FWHM, nnaida3 77 ch FWHM - cf. 73 & 78 ch FWHM respectively 10.41 yesterday
1.8.H spectra - see attcahments 26-27
p+n FEE64s 1.8.W spectra 20us FSR - attachment 28
n+n FEE64s 1.8.W spectra 20us FSR - attachment 29
11.30 Check ASIC Control *all* FEE64s & ASICs
zero *all* histograms
zero DAQ stats
11.50 analysis of RIBF147/R2_576
deadtime *all* FEE64s <<1%
no timewarps
11.57 ADC data synchronised - attachment 30
per FEE64 ADC data / 20.48us - attachment 31
12:39 DTAS and BigRIPS stop runs
AIDA on file R2_585
DTAS file 101
BigRIPS run 2043
AIDA on File R2_585
13:23 System wide checks ok
14:38 DTAS and BigRIPS stop runs
AIDA on file R2_683
OH offline analysis of BigRIPS-implant correlations for previous 2h indicates >90% of 100Sn are
now in DSSSD#2 with small d=fraction remaining in DSSSD#3
100Sn setting, 0.3mm Al degrader
ASIC settings 2019Jun13-08.56.35
DSSSD#1 slow comparator 0xa -> 0x1d
DSSSD#2 slow comparator 0xa -> 0x8
DSSSD#3 slow comparator 0x8 -> 0xa
DAQ stats before & after chn age of slow comparator thresholds above - see attachments 33 & 34
before 11x <20k 21x <50k 24x <100k cf after 11x <20k 22x <50k 23x <100k
merger 664k items/s cf 560k data items/s
BNC PB-4 Pulser
Amplitude 90,000
x5 attenuator IN
Frequency 25Hz range, variable min. c. 2.5Hz
t_r 100ns, tau_d 50us
- polarity
Delay MIN, tail pulse
15.03 DAQ start
AIDA file R2_606
DTAS file 104
BigRIPS run 2044
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|