Message ID: 852
Entry time: Tue Jun 18 08:03:20 2019
|
Author: |
DK |
Subject: |
Tuesday 18 June 16:00 - 24:00 |
|
|
Shift change
16:00
115 pnA primary, 290 cps implants at F11
Presently at AIDA R2_616
DAQ is running smoothly - passes all system checks (except ADC calib of nnaida7)
Stats okay, though nnaida19 and 24 running a bit high (seems consistent w/ previous shift) - attach 1
(Consistent with lower thresholds, pasted below)
100Sn setting, 0.3mm Al degrader
ASIC settings 2019Jun13-08.56.35
DSSSD#1 slow comparator 0xa -> 0x1d
DSSSD#2 slow comparator 0xa -> 0x8
DSSSD#3 slow comparator 0x8 -> 0xa
Biases fine - attach 2
Merger okay - attach 3
TapeServer okay - attach 4
16:13 New DTAS run 105
AIDA R2_618
BigRIPS is still 2044 as at 15:03
Temperatures okay - attach 5
16:20 Implant spectra look good, mainly into DSSSD2 - attach 6
Spectra saved in ~spectra/specs-2019Jun18-16.24.33
16:30 Zero stats, histograms
17:03 Old runs ending
AIDA R2_626
In principle DTAS 106 but it switches quickly to 107
BigRIPS 2045
17:10 New run DTAS 108, AIDA R2_627
18:09 New implant profile - attach 6
New stats - attach 7
Looks okay
19:08 AIDA R2_647, DTAS 110
19:14 AIDA R2_648, DTAS 111, BigRIPS 2046
20:08 XY implants - attach 8
Bias - attach 9
Merger - attach 10
TapeServer - attach 11
Stats - attach 12
21:15 New runs: BigRIPS 2047, DTAS 115, AIDA R2_668
22:37 XY - attached 13; stats - attached 14
Primary beam at 120 pnA; implants around 250 cps at F11
23:14 DTAS closes the run
23:20 New runs: AIDA R2_688, DTAS 118, BigRIPS 2048 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|