  241   Fri Mar 31 00:01:55 2017 ID JA DK GK LiuRun 030
Date: 31/03/2017
Start: 07:58
BRIKEN run: 30
AIDA Run: R16_471
BigRIPS run: 173
DLT:170331_0630_Mg40_030.dlt

BRIKEN Rate:40
F11 Rate:11


Date:  31/03/2017
Stop: 8:57
BRIKEN run: 30
AIDA Run: R16_485
BigRIPS run: 173

Root file:170331_0012_0857_B030_Mg40.root
OBSERVATIONS:
  271   Sat Apr 1 04:03:31 2017 ID JA DK GKNa37 Ne36 run 056
Date: 1/04/2017
Start:12:00
BRIKEN run: 56
AIDA Run: R20_131
BigRIPS run: 209
DLT:170401_1200_Na37_056.dlt


BRIKEN Rate: 1.5 cps
F11 Rate: 8.5 cps

Date: 1/04/2017
Stop: 12:58
BRIKEN run: 56 
AIDA Run: R20_176
BigRIPS run: 0209

Root file: 170401_0157_1159_B056_Na37Ne36.root
OBSERVATIONS: spectra was NOT cleared
  268   Sat Apr 1 00:04:10 2017 ID GK DK Liu37Na or 36Ne labels?
The BigRIPS settings are all called "36Ne setting" but the night shift labels these runs in the BRIKEN DAQ as
"37Na". We are not sure why we label it with 37Na, we think this should be consistently named 36Ne like the
BigRIPS settings. (For sure the strongest component in the beam might be 37Na. In the 39Na settings before it
was 40Mg and we labelled it 40Mg...)
  269   Sat Apr 1 01:04:31 2017 ID DK JANa37 Ne36 Run 54
Date: 1/04/2017
Start: 09:03
BRIKEN run: 54
AIDA Run: R20_115903
BigRIPS run: 206
DLT: 170401_0741_Na37_053.dlt
(change name, wrong starting time) corrected to 170401_0903_Na37_054.dlt

BRIKEN Rate: 1.5 cps
F11 Rate: 8.5 cps

Date: 1/04/2017
Stop: 
BRIKEN run: 54
AIDA Run: R20_130
BigRIPS run: 206

Root file: 170401_0157_1004_B054_Na37Ne36.root

OBSERVATIONS: PPAC discharges every ~10min (got better)
  270   Sat Apr 1 02:07:49 2017 ID DK JARun 55
Date: 1/04/2017
Start:10:04
BRIKEN run: 55
AIDA Run: R20_131
BigRIPS run: 207
DLT:170401_1002_Na37_055.dlt


BRIKEN Rate: 1.5 cps
F11 Rate: 8.5 cps

Date: 1/04/2017
Stop: 11:59
BRIKEN run: 55
AIDA Run: R20_160
BigRIPS run: 208

Root file: 170401_0157_1159_B055_Na37Ne36.root
OBSERVATIONS: 10:55 Beam stop few minutes
F11_PL_R Change the range and cleared 
Two Big rips files
  272   Sat Apr 1 05:01:24 2017 ID DK GK JLT36Ne 37Na run 057
Date: 1/04/2017
Start:13:00
BRIKEN run: 57
AIDA Run: R20_176
BigRIPS run: 210
DLT:170401_1200_Na37_057.dlt
(wrong starting time, should read 1300)

BRIKEN Rate: 1.5 cps
F11 Rate: 8.5 cps

Date: 1/04/2017
Stop: 14:44
BRIKEN run:  57
AIDA Run: R20_203
BigRIPS run: 210

Root file: 
OBSERVATIONS: spectra was NOT cleared. Some time with lower rates around 14:00
  173   Sat Nov 26 09:31:05 2016 Gabor Kiss, Ariel Tarifeno, Alvaro TolosaOutput signals from G7Red
Preamplifier of crystal G7Red was replaced. 
Output signals from G7Red are weird.

Several screen-shots of the signal are attached. The time calibration factor is 20ns/sample. 
  4   Mon Feb 16 00:29:00 2015 Gabor KISSPolyethyelene

The polyethelene arrived at RIKEN. Except 4 neighboring holes (located at the inner ring) the alignment is OK.

  305   Fri May 26 03:24:38 2017 GK,VP, AT, AACLOVER, 133Ba
133Ba source efficiency calibration, no AIDA

Start: 11:23
Stop: 11:43

Files: 
170526_1123_133Ba_noAIDA_z0cm_015.dlt
170526_1123_1143_133Ba_z0cm.root
  236   Thu Mar 30 19:16:46 2017 GK,DK,JLiu,JA,JLT40 Mg run 24
Date: 31/03/2017
Start: 03:14
BRIKEN run: 24
AIDA Run: R16_402
BigRIPS run: 168
DLT: 170331_0314_Mg40_024.dlt

BRIKEN Rate: 4
F11 Rate: 13


Date:  31/03/2017
Stop: 04:10
BRIKEN run: 24
AIDA Run: R16_416
BigRIPS run: 169

Root file: 170331_0012_0409_B024_Mg40.root
OBSERVATIONS: Previous online was cleared
  177   Sat Nov 26 20:50:13 2016 GK, AT&ATrun 16-19
=======    START    =======
Date 2016/11/26
Start time	: 17:21
BRIKEN run	: 016
Daq Conf. File	: 161125Conf_BrikenFull.xlsx
DLT File name	: 161126_1721_016
AIDA run	: R9-24
AIDA start	: 16:35
BigRIPS run	: 40Mg-1009
BigRIPS start	: 
---------------------------
Shifters:  GK, AT&AT
=======    Setup    =======
Central fragment:  41Al
--- Degraders ---
 Fixed: 3mm Pb between Musics 
 Variable: 
1=(0.5mm W+1mm Al), 2=(0.3mm W+1mm Al), 3=(1mm W +1mm Al)
1. OUT
2. IN
3. IN

=======  COMMENTS   =======
High gamma counting is affecting rings 1-4. (gammas in beam!?) 

------  Rates  ------
BRIKEN	:    1.12118e+02 cps
F11R	:    6.26962 cps
Clovers	:    1.72406e+04 cps
VPLT	:    1.82165e+01 cps
VPLB	:    9.08055 cps
AIDAPL	:    7.42954 cps

=========   END   =========
Date 2016/11/26
BRIKEN run	: 019
BRIKEN stop	: 18:04
ROOT online	: 161126_1823_016_019.root
AIDA run	: R9-43
AIDA stop	: 18:12
BigRIPS RUN	: 
  7   Sat Apr 25 08:25:42 2015 G. Kiss, J. AgramuntBRIKEN Test setup

Altogether 16  tubes are mounted for the parasitic detector test (see the attached photos):

- two tubes (belonging to RIKEN) are in a 10 cm x 10 cm x 30 cm polyethylene matrix inside Eurica, the distance from AIDA is about 30 cm

- 12 tubes (belonging to RIKEN) are in a 20 xm x 30 xm x 30 cm matrix, outside (below) Eurica, at the closest possible place to AIDA, the distance is about 60 cm

- further two tubes (ORNL) are at the bottom of the Eurica support, about 1.2 m from the AIDA Silicon.

Furthermore, spectra measured using a 252Cf source is attached to this report, too (Jap1Cf-RIKEN tube, Us1Cf-ORNL tube). At the moment a background measurement is running.P1120020.JPG

  8   Mon Apr 27 04:40:43 2015 G. Kiss, J. Agramuntneutron background at Eurica

Based on an about 8h long background measurement, the neutron background at the Eurica site was found to be about 0.006 neutron / sec (in the Riken tubes) and 0.019 neutron / sec (in the ORNL tubes). The beam was OFF.

  29   Mon May 11 09:14:54 2015 G. Kiss252Cf_data_sheet

The activity of the 252Cf source, used for the calibration was 3.7 MBq at 15.05.2006. Unfortunately, uncertainty is missing from the data sheet :-(252Cf_15_05_2006_3p7MBq.jpg

  407   Mon Nov 5 09:32:00 2018 FM, JR, PA, ATLow threshold, 252Cf, z=0cm, Perpendicular 0deg
252Cf at z=0cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.

18/11/05 START: 18:50
18/11/05 STOP:  20:45


** Configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx


ROOT file: 

181105_1850_252Cf_z0cm_2045.root


DLT files:

181105_1850_252Cf_z0cm_133.dlt
181105_1850_252Cf_z0cm_134.dlt
181105_1850_252Cf_z0cm_135.dlt
181105_1850_252Cf_z0cm_136.dlt




Comment: 
- Clovers are placed inside the moderator, front face ~5mm from AIDA hole border.
- AIDA not inside the moderator.
- In beam PE shielding placed.
  409   Mon Nov 5 12:04:08 2018 FM, PA, ATLow threshold, 252Cf, z=15cm, Perpendicular 0deg
252Cf at z=15cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.

18/11/05 START: 21:05
18/11/05 STOP:  22.30


** Configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx


ROOT file: 

181105_2105_252Cf_z15cm_2230.root


DLT files:

181105_2105_252Cf_z15cm_137.dlt
181105_2105_252Cf_z15cm_138.dlt
181105_2105_252Cf_z15cm_139.dlt




Comment: 
- Clovers are placed inside the moderator, front face ~5mm from AIDA hole border.
- AIDA not inside the moderator.
- In beam PE shielding placed.
  411   Mon Nov 5 15:10:43 2018 FM, PA,Low threshold, 252Cf, z=15cm, Parallel downstream
252Cf at z=15cm, i.e 15 cm from the center of the detector,  source axis parallel downstream 
Low threshold.

18/11/06 START: 00:10
18/11/06 STOP:  01:32


** Configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx


ROOT file: 

181106_0010_252Cf_z15cm_0132.root



DLT files:

181106_0010_252Cf_z15cm_143.dlt
181106_0010_252Cf_z15cm_144.dlt
181106_0010_252Cf_z15cm_145.dlt





Comment: 
- Clovers are placed inside the moderator, front face ~5mm from AIDA hole border.
- AIDA not inside the moderator.
- In beam PE shielding placed.
  412   Mon Nov 5 16:43:43 2018 FM, PA,Low threshold, 252Cf, z=25cm, Parallel downstream
252Cf at z=25cm, i.e 25 cm from the center of the detector,  source axis parallel downstream 
Low threshold.

18/11/06 START: 01:43
18/11/06 STOP:  03:03


** Configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx


ROOT file: 

181106_0143_252Cf_z25cm_0303.root



DLT files:

181106_0143_252Cf_z25cm_146.dlt
181106_0143_252Cf_z25cm_147.dlt





Comment: 
- Clovers are placed inside the moderator, front face ~5mm from AIDA hole border.
- AIDA not inside the moderator.
- In beam PE shielding placed.
  410   Mon Nov 5 13:43:57 2018 FM, PALow threshold, 252Cf, z=0cm, Parallel downstream
252Cf at z=0cm,ie center of moderator, source axis parallel downstream 
Low threshold.

18/11/05 START: 22:46
18/11/05 STOP:  00:01


** Configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx


ROOT file: 

181105_2245_252Cf_z0cm_0001.root


DLT files:

181105_2245_252Cf_z0cm_140.dlt
181105_2245_252Cf_z0cm_141.dlt
181105_2245_252Cf_z0cm_142.dlt



Comment: 
- Clovers are placed inside the moderator, front face ~5mm from AIDA hole border.
- AIDA not inside the moderator.
- In beam PE shielding placed.
  206   Tue Mar 28 17:02:19 2017 DKApplying Biases
Today, Gabor and I discussed with Nathan from ORNL about the biasing system used for Ge, 3He, Plastic, and others.  Phong is also a bit familiar with the system (edit also 
Shintaro 
Go).  While there 
is supposed to be a manual, Gabor and I did not find it.
In case of trouble: contact Nathan Brewer Gmail: Brewer.nathant@gmail.com Skype: nathan.t.brewer

Log in to high voltage PC:

$ ssh -Y pixie16@10.32.6.161
passwd: ************

For HV readout, run firefox in the background

$ firefox &

You can probably check the history or restore pages, but it should be pointed
at 192.168.13.239

It updates automatically every several seconds.  Unless the HV monitor is
running, it may show nothing...

For temperatures:

$ cd ~/DAQ_1/kelvin
$ ./kelvin-read

(there are options to kill all temperatures)

For applying existing HVs (BE CAREFUL!)

$ cd ~/DAQ_1/hv-mpod
$ ./hvmon

If you want to change the voltages (up or down) kill this with Ctrl+C

To alter bias values or change which ones are on, you can edit the file:

$ ~/DAQ_1/include/hvmon.conf

Once the file is saved, restart hvmon.

We are running the above in a GNU screen session, with firefox on one computer.  It has a note taped to it.  Please don't use this computer for other purposes unless necessary!  
Let me note that the PC we log in through has essentially no .screenrc file so you can barely understand you are actually using screen.  If you are not very familiar with 
screen, better not to touch it.  I will put a better .screenrc later (but I also don't want to change the setup now).

28 Mar 2017 15:47:31

Ge voltage application

LN2 filling was done yesterday before lunch

D is the beam left side Ge
	MPOD	name
	U300	D4K
	U301	D4R
	U302	D4G
	U303	D4B

83.7 K, with 300 V

G is the beam right side Ge
	MPOD 	name
	U304	G7K
	U305	G7R
	U306	G7G
	U307	G7B

79.6 K with 250 V (except G7R at 300 V)

All analog signals are seen in the oscilloscope with reasonable behavior

28 Mar 2017 15:56:03 

Ramp up all Ge clovers.

D at 3000 V for all

G at 2500 V for all (except G7R is 3000)

28 Mar 2017 16:26:39 

Biases are all applied (maybe several minutes earlier)

D4 temp 83.7 K
G7 temp 79.6 K

28 Mar 2017 17:51:09 

Now we ramp up 3He and plastics.  We keep the Ge on during this time.

D4 83.7 K
G7 79.6 K

Everything looks good!
ELOG V3.1.3-7933898