Fri Mar 31 00:01:55 2017, ID JA DK GK Liu, Run 030
|
Date: 31/03/2017
Start: 07:58
BRIKEN run: 30
|
Sat Apr 1 04:03:31 2017, ID JA DK GK, Na37 Ne36 run 056
|
Date: 1/04/2017
Start:12:00
BRIKEN run: 56
|
Sat Apr 1 00:04:10 2017, ID GK DK Liu, 37Na or 36Ne labels?
|
The BigRIPS settings are all called "36Ne setting" but the night shift labels these runs in the BRIKEN DAQ as
"37Na". We are not sure why we label it with 37Na, we think this should be consistently named 36Ne like the
BigRIPS settings. (For sure the strongest component in the beam might be 37Na. In the 39Na settings before it
|
Sat Apr 1 01:04:31 2017, ID DK JA, Na37 Ne36 Run 54
|
Date: 1/04/2017
Start: 09:03
BRIKEN run: 54
|
Sat Apr 1 02:07:49 2017, ID DK JA, Run 55
|
Date: 1/04/2017
Start:10:04
BRIKEN run: 55
|
Sat Apr 1 05:01:24 2017, ID DK GK JLT, 36Ne 37Na run 057
|
Date: 1/04/2017
Start:13:00
BRIKEN run: 57
|
Sat Nov 26 09:31:05 2016, Gabor Kiss, Ariel Tarifeno, Alvaro Tolosa, Output signals from G7Red   
|
Preamplifier of crystal G7Red was replaced.
Output signals from G7Red are weird.
|
Mon Feb 16 00:29:00 2015, Gabor KISS, Polyethyelene 
|
| The polyethelene arrived at RIKEN. Except 4 neighboring holes (located at the inner ring) the alignment is OK. |
Fri May 26 03:24:38 2017, GK,VP, AT, AA, CLOVER, 133Ba
|
133Ba source efficiency calibration, no AIDA
Start: 11:23
|
Thu Mar 30 19:16:46 2017, GK,DK,JLiu,JA,JLT, 40 Mg run 24
|
Date: 31/03/2017
Start: 03:14
BRIKEN run: 24
|
Sat Nov 26 20:50:13 2016, GK, AT&AT, run 16-19 
|
======= START =======
Date 2016/11/26
Start time : 17:21
|
Sat Apr 25 08:25:42 2015, G. Kiss, J. Agramunt, BRIKEN Test setup   
|
Altogether 16 tubes are mounted for the parasitic detector test (see the attached photos):
- two tubes (belonging to RIKEN) are in a 10 cm x 10 cm x 30 cm polyethylene matrix inside Eurica, the distance from AIDA is about 30 cm
- 12 tubes (belonging to RIKEN) are in a 20 xm x 30 xm x 30 cm matrix, outside (below) Eurica, at the closest possible place to AIDA, the distance |
Mon Apr 27 04:40:43 2015, G. Kiss, J. Agramunt, neutron background at Eurica
|
Based on an about 8h long background measurement, the neutron background at the Eurica site was found to be about 0.006 neutron / sec (in the Riken tubes)
and 0.019 neutron / sec (in the ORNL tubes). The beam was OFF. |
Mon May 11 09:14:54 2015, G. Kiss, 252Cf_data_sheet
|
| The activity of the 252Cf source, used for the calibration was 3.7 MBq at 15.05.2006. Unfortunately, uncertainty is missing from the data sheet :-( |
Mon Nov 5 09:32:00 2018, FM, JR, PA, AT, Low threshold, 252Cf, z=0cm, Perpendicular 0deg
|
252Cf at z=0cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.
|
Mon Nov 5 12:04:08 2018, FM, PA, AT, Low threshold, 252Cf, z=15cm, Perpendicular 0deg
|
252Cf at z=15cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.
|
Mon Nov 5 15:10:43 2018, FM, PA,, Low threshold, 252Cf, z=15cm, Parallel downstream
|
252Cf at z=15cm, i.e 15 cm from the center of the detector, source axis parallel downstream
Low threshold.
|
Mon Nov 5 16:43:43 2018, FM, PA,, Low threshold, 252Cf, z=25cm, Parallel downstream
|
252Cf at z=25cm, i.e 25 cm from the center of the detector, source axis parallel downstream
Low threshold.
|
Mon Nov 5 13:43:57 2018, FM, PA, Low threshold, 252Cf, z=0cm, Parallel downstream
|
252Cf at z=0cm,ie center of moderator, source axis parallel downstream
Low threshold.
|
Tue Mar 28 17:02:19 2017, DK, Applying Biases
|
Today, Gabor and I discussed with Nathan from ORNL about the biasing system used for Ge, 3He, Plastic, and others. Phong is also a bit familiar with the
system (edit also
Shintaro
|